EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Dynamics of Anterior Chamber Angle Parameters in Primary and Secondary Pseudophakic Eyes Following Congenital Cataract Surgery

Siyan Li, Jiaying Wu, Dandan Wang, Ruiwen Zhang, Yinying Zhao, Hongfang Zhang, Xixia Ding, Pingjun Chang, Yun-E Zhao

Translational Vision Science & Technology · 2026

DOI: 10.1167/tvst.15.2.2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Translational Vision Science & Technology, 2026. Verfasst von Siyan Li und 8 weiteren Autor:innen. Beteiligte Einrichtung: National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, China. Hauptthemen laut MEDLINE: Anterior Chamber, Pseudophakia, Cataract Extraction, Cataract. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate anterior chamber angle (ACA) parameter changes and their correlation with intraocular pressure (IOP) in primary versus secondary intraocular lens (IOL) implantation following congenital cataract (CC) surgery, using swept-source anterior segment optical coherence tomography (SS-ASOCT).

Methods

Preoperative and postoperative (1 and 6 months) SS-ASOCT images from 89 eyes of 64 patients undergoing CC surgery were analyzed. ACA parameters (AOD500, ARA500, TISA500, TIA500) were measured. Generalized estimating equations assessed ACA parameter changes, and multivariable analysis determined relationships between ACA parameters and IOP.

Results

Compared to normal eyes, aphakic eyes showed larger AOD500 and ARA500 but smaller TISA500 (P < 0.05). After IOL implantation, both primary and secondary pseudophakic eyes (P-PsE and S-PsE) exhibited significant postoperative reductions in ARA500 and TISA500 (P < 0.05), mainly in the nasal angle. Multivariable analysis revealed corneal thickness positively correlated with IOP in both groups, while nasal AOD500 (β = -0.685, P < 0.05) and nasal TIA500 (β = -0.109; P < 0.001) showed negative associations in S-PsE. Angle abnormalities were identified during the annotation of images, associated with poorer visual outcomes.

Conclusions

Significant postoperative reductions in ARA500 and TISA500 occurred in both primary and secondary IOL implantation for CC, predominantly in the nasal angle. Although overall angle parameters were comparable, S-PsEs uniquely demonstrated IOP correlations with pupil diameter and nasal angle, suggesting distinct IOP regulation mechanisms. Translational Relevance: SS-ASOCT-derived nasal anterior chamber angle metrics may provide an accessible biomarker for monitoring angle remodeling and intraocular pressure regulation following congenital cataract surgery.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Anterior ChamberPseudophakiaCataract ExtractionCataractHumansFemaleMaleLens Implantation, IntraocularTomography, Optical CoherenceIntraocular PressureChild, PreschoolPostoperative PeriodInfantVisual Acuity

Autor:innen und Institutionen

  • National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, China.
  • Eye Hospital of Wenzhou Medical University at Hangzhou, Hangzhou, China.

Zitieren

APA

Li, S., Wu, J., Wang, D., Zhang, R., Zhao, Y., Zhang, H., Ding, X., Chang, P., & Zhao, Y. E. (2026). Dynamics of Anterior Chamber Angle Parameters in Primary and Secondary Pseudophakic Eyes Following Congenital Cataract Surgery. Translational Vision Science & Technology. https://doi.org/10.1167/tvst.15.2.2

Vancouver

Li S, Wu J, Wang D, Zhang R, Zhao Y, Zhang H, et al. Dynamics of Anterior Chamber Angle Parameters in Primary and Secondary Pseudophakic Eyes Following Congenital Cataract Surgery. Translational Vision Science & Technology. 2026. doi:10.1167/tvst.15.2.2

BibTeX
@article{Li2026,
  author = {Li, Siyan and Wu, Jiaying and Wang, Dandan and Zhang, Ruiwen and Zhao, Yinying and Zhang, Hongfang and Ding, Xixia and Chang, Pingjun and Zhao, Yun-E},
  title = {Dynamics of Anterior Chamber Angle Parameters in Primary and Secondary Pseudophakic Eyes Following Congenital Cataract Surgery},
  journal = {Translational Vision Science & Technology},
  year = {2026},
  doi = {10.1167/tvst.15.2.2}
}
Kostenlos starten →