EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Circumferential Identification of Peripheral Anterior Synechiae by Air-Puff Dynamic Anterior Segment Optical Coherence Tomography

Xikai Wei, Cheng Lu, Jianli Ren, Kaixi Zheng, Shaodan Zhang, Peijuan Wang, Dexi Zhu

Translational Vision Science & Technology · 18.11.2026 · 15 (11) · 17

DOI: 10.1167/tvst.15.11.17 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Translational Vision Science & Technology, erschienen am 18.11.2026. Verfasst von Xikai Wei und 6 weiteren Autor:innen. Beteiligte Einrichtung: Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, People's Republic of China. Hauptthemen laut MEDLINE: Tomography, Optical Coherence, Glaucoma, Angle-Closure, Anterior Eye Segment, Anterior Chamber. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The purpose of this study was to objectively and accurately identify peripheral anterior synechiae (PAS) circumferentially in eyes with angle-closure glaucoma (ACG).

Methods

Anterior chamber angles (ACAs) were classified as PAS or non-PAS (NPAS) groups by indentation gonioscopy. A custom-built air-puff dynamic anterior segment optical coherence tomography (DAS-OCT) system with an innovative 4-leaf clover-scan pattern acquired 10 frames per ACA along 8 radial directions at 45-degree intervals within 65 ms. Dynamic parameters including the differences in angle opening distance at 750 µm from the scleral spur (AOD750) and trabecular-iris space area at 750 µm anterior to the scleral spur (TISA750) before and after air-puff stimulation, were extracted to establish a binary logistic regression model. Model performance was evaluated in the testing set.

Results

Analysis of 68 images from 9 healthy eyes confirmed high measurement repeatability (intraclass correlation coefficient [ICC] = 0.821 for AOD750dif; 0.775 for TISA750dif). A total of 143 anterior segment OCT (AS-OCT) images from 20 ACG eyes were analyzed, with 100 assigned to the training set and 43 to the testing set. Significant differences in AOD750dif and TISA750dif were identified between the NPAS and PAS groups (P < 0.001). The dual-parameter model achieved an area under the curve (AUC) of 0.924 in the training set and 0.913 in the testing set, with an overall accuracy of 83.7%.

Conclusions

The air-puff DAS-OCT system enables the noninvasive, dynamic, and circumferential identification of PAS, demonstrating high diagnostic performance. Translational Relevance: This non-contact imaging technology offers a quantitative alternative to indentation gonioscopy, potentially improving ACG screening efficiency and guiding clinical management.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, Optical CoherenceGlaucoma, Angle-ClosureAnterior Eye SegmentAnterior ChamberHumansGonioscopyMaleReproducibility of ResultsFemaleAirIntraocular Pressure

Autor:innen und Institutionen

  • Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, People's Republic of China.
  • National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, People's Republic of China.

Zitieren

APA

Wei, X., Lu, C., Ren, J., Zheng, K., Zhang, S., Wang, P., & Zhu, D. (2026). Circumferential Identification of Peripheral Anterior Synechiae by Air-Puff Dynamic Anterior Segment Optical Coherence Tomography. Translational Vision Science & Technology, 15(11), 17. https://doi.org/10.1167/tvst.15.11.17

Vancouver

Wei X, Lu C, Ren J, Zheng K, Zhang S, Wang P, et al. Circumferential Identification of Peripheral Anterior Synechiae by Air-Puff Dynamic Anterior Segment Optical Coherence Tomography. Translational Vision Science & Technology. 2026;15(11):17. doi:10.1167/tvst.15.11.17

BibTeX
@article{Wei2026,
  author = {Wei, Xikai and Lu, Cheng and Ren, Jianli and Zheng, Kaixi and Zhang, Shaodan and Wang, Peijuan and Zhu, Dexi},
  title = {Circumferential Identification of Peripheral Anterior Synechiae by Air-Puff Dynamic Anterior Segment Optical Coherence Tomography},
  journal = {Translational Vision Science & Technology},
  year = {2026},
  volume = {15},
  number = {11},
  pages = {17},
  doi = {10.1167/tvst.15.11.17}
}
Kostenlos starten →