EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Analysis of In Vivo Sclera Impact on the Biomechanics of Myopic Eyes

Ruisi Xie, Yan Huo, Yutong Li, Zhengyuan Qu, Haohan Zou, Yan Wang

Translational Vision Science & Technology · 03.06.2025 · 14 (6) · 8

DOI: 10.1167/tvst.14.6.8 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Translational Vision Science & Technology, erschienen am 03.06.2025. Verfasst von Ruisi Xie und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Medicine, Nankai University, Tianjin, China. Hauptthemen laut MEDLINE: Sclera, Myopia, Cornea. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The purpose of this study was to evaluate the relationship between in vivo scleral thickness and biomechanical properties in eyes with myopia and to examine the association between in vivo sclera and the severity of myopia.

Methods

This prospective case series included 101 eyes from 101 patients with myopia. Corneal biomechanical parameters and anterior scleral images were acquired using the Corvis ST and anterior segment optical coherence tomography (AS-OCT), respectively. Anterior scleral thickness (AST) was measured at the scleral spur (AST0), and at 1 mm (AST1), 2 mm (AST2), and 3 mm (AST3) along the nasal (NAST) and temporal (TAST) regions. The correlations among corneal biomechanical parameters, AST, axial length (AL), and spherical equivalent refraction (SER) were analyzed after adjusting for confounding factors.

Results

The scleral spur (AST0) was thicker than the other regions (P < 0.0001). After adjusting for confounding factors, the corneal biomechanical parameters, the stiffness parameter at highest concavity (SP-HC) was significantly related to scleral thickness (P < 0.05, rNAST0 = 0.369, rNAST1 = 0.236, rNAST2 = 0.217, and rTAST0 = 0.480). SP-HC (r = 0.223) and peak distance (r = -0.259) were significantly related to SER (P < 0.05).

Conclusions

Scleral thickness, particularly at the scleral spur, is an important factor influencing in vivo biomechanics of myopic eyes. The stiffness parameter SP-HC showed the strongest correlation with in vivo AST, potentially reflecting scleral biomechanical properties. SP-HC decreased significantly with increasing myopia, suggesting that weaker scleral biomechanics may be a risk factor for myopia progression. Translational Relevance: In vivo stiffness parameter SP-HC may indirectly quantify scleral properties and serve as a high-risk biomechanical indicator to evaluate myopia progression.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ScleraMyopiaCorneaHumansMaleFemaleTomography, Optical CoherenceAdultProspective StudiesBiomechanical PhenomenaYoung AdultRefraction, OcularMiddle Aged

Autor:innen und Institutionen

  • School of Medicine, Nankai University, Tianjin, China.
  • Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China.
  • Tianjin Eye Hospital, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Institute, Nankai University Affiliated Eye Hospital, Tianjin, China.
  • Nankai University Eye Institute, Nankai University, Tianjin, China.
  • https://orcid.org/0000-0002-1257-6635.

Zitieren

APA

Xie, R., Huo, Y., Li, Y., Qu, Z., Zou, H., & Wang, Y. (2025). Analysis of In Vivo Sclera Impact on the Biomechanics of Myopic Eyes. Translational Vision Science & Technology, 14(6), 8. https://doi.org/10.1167/tvst.14.6.8

Vancouver

Xie R, Huo Y, Li Y, Qu Z, Zou H, Wang Y. Analysis of In Vivo Sclera Impact on the Biomechanics of Myopic Eyes. Translational Vision Science & Technology. 2025;14(6):8. doi:10.1167/tvst.14.6.8

BibTeX
@article{Xie2025,
  author = {Xie, Ruisi and Huo, Yan and Li, Yutong and Qu, Zhengyuan and Zou, Haohan and Wang, Yan},
  title = {Analysis of In Vivo Sclera Impact on the Biomechanics of Myopic Eyes},
  journal = {Translational Vision Science & Technology},
  year = {2025},
  volume = {14},
  number = {6},
  pages = {8},
  doi = {10.1167/tvst.14.6.8}
}
Kostenlos starten →