EUVIMEDEUVIMED entdecken
BeobachtungsstudieOpen Access · CC BY-NC-ND 4.0

Face and Available Chair Detection and Localization With a Second-Generation (44-Channel) Suprachoroidal Retinal Prosthesis

Lisa Lombardi, Matthew A Petoe, Lauren Moussallem, Maria Kolic, Elizabeth K Baglin, Samuel Stefopoulos, Xerxes Battiwalla, Janine G Walker, Nick Barnes, Carla J Abbott, Penelope J Allen, Bionics Institute and Centre for Eye Research Australia Retinal Prosthesis Consortium

Translational Vision Science & Technology · 2025

DOI: 10.1167/tvst.14.5.11 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Translational Vision Science & Technology, 2025. Verfasst von Lisa Lombardi und 11 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Eye Research Australia, Royal Victorian Eye & Ear Hospital, East Melbourne, VIC, Australia. Hauptthemen laut MEDLINE: Face, Visual Prosthesis. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To compare accuracy of the comprehensive vision processing (VP) algorithm (Lanczos2 [L2]) with the novel VP algorithms, face detection (FaD) and available chair detection (ChD) methods in recipients of the second-generation suprachoroidal retinal prosthesis.

Methods

Four suprachoroidal retinal prosthesis recipients (#NCT05158049) were acclimatized to new VP methods (FaD and ChD) with L2 used as control. For face localization, one or two mannequins (white/black) were forward or backward facing in three positions in a room with a white backdrop. Participants were asked to detect the number of mannequins and faces present and point to the forward-facing mannequin. For available chair localization, two mannequins (white/black) were seated in two of three chairs (white/black). Participants were asked to detect and navigate to the available chair.

Results

FaD performed significantly better than L2 for correct face detection (FaD) (81.25 ± 10.21%; L2 32.81 ± 5.98%; P = 0.029) and for face localization (FaD, 81.25 ± 10.21%; L2, 26.56 ± 10.67%; P = 0.029). The accuracy of mannequin detection was equivalent between FaD (47.22 ± 5.56%) and L2 (52.78 ± 13.98%) with one mannequin (P = 0.457), and with two mannequins present (FaD, 21.43 ± 18.44%; L2. 3.57 ± 7.14%; P = 0.257). The ChD VP method (88.89 ± 12.00% correct) performed significantly better than L2 (19.44 ± 13.22%) for localizing available chairs (P = 0.029).

Conclusions

FaD and ChD VP methods performed better than L2 for the purpose of localizing faces and available chairs, respectively. Translational Relevance: New VP algorithms can improve the localization of specific object types while using the second-generation suprachoroidal retinal prosthesis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

FaceVisual ProsthesisAdultFemaleHumansMaleMiddle AgedAlgorithmsManikinsProsthesis Design

Autor:innen und Institutionen

  • Centre for Eye Research Australia, Royal Victorian Eye & Ear Hospital, East Melbourne, VIC, Australia.
  • Bionics Institute, East Melbourne, VIC, Australia.
  • Medical Bionics Department, University of Melbourne, Melbourne, VIC, Australia.
  • Bionic Vision Technologies Pty Ltd, Docklands, VIC, Australia.
  • Health & Biosecurity, Commonwealth Scientific and Industrial Research Organisation, Black Mountain, ACT, Australia.
  • School of Computing, Australian National University, Canberra, ACT, Australia.

Zitieren

APA

Lombardi, L., Petoe, M. A., Moussallem, L., Kolic, M., Baglin, E. K., Stefopoulos, S., Battiwalla, X., Walker, J. G., Barnes, N., Abbott, C. J., Allen, P. J., & Bionics Institute and Centre for Eye Research Australia Retinal Prosthesis Consortium (2025). Face and Available Chair Detection and Localization With a Second-Generation (44-Channel) Suprachoroidal Retinal Prosthesis. Translational Vision Science & Technology. https://doi.org/10.1167/tvst.14.5.11

Vancouver

Lombardi L, Petoe MA, Moussallem L, Kolic M, Baglin EK, Stefopoulos S, et al. Face and Available Chair Detection and Localization With a Second-Generation (44-Channel) Suprachoroidal Retinal Prosthesis. Translational Vision Science & Technology. 2025. doi:10.1167/tvst.14.5.11

BibTeX
@article{Lombardi2025,
  author = {Lombardi, Lisa and Petoe, Matthew A and Moussallem, Lauren and Kolic, Maria and Baglin, Elizabeth K and Stefopoulos, Samuel and Battiwalla, Xerxes and Walker, Janine G and Barnes, Nick and Abbott, Carla J and Allen, Penelope J and Bionics Institute and Centre for Eye Research Australia Retinal Prosthesis Consortium, Bionics Institute and Centre for Eye Research Australia Retinal Prosthesis Consortium},
  title = {Face and Available Chair Detection and Localization With a Second-Generation (44-Channel) Suprachoroidal Retinal Prosthesis},
  journal = {Translational Vision Science & Technology},
  year = {2025},
  doi = {10.1167/tvst.14.5.11}
}
Kostenlos starten →