Evaluation of the Long-Term Corneal Biomechanics Following SMILE With Different Residual Stromal Bed Thickness in Rabbits
Translational Vision Science & Technology · 2025
DOI: 10.1167/tvst.14.3.3 ↗Kurz gefasst
Fachartikel in der Zeitschrift Translational Vision Science & Technology, 2025. Verfasst von Hongwei Qin und 12 weiteren Autor:innen. Beteiligte Einrichtung: College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, China. Hauptthemen laut MEDLINE: Corneal Stroma, Cornea, Myopia, Corneal Surgery, Laser. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Purpose
The long-term safety of small-incision lenticule extraction (SMILE) surgery for correcting high myopia with a residual stromal bed thickness (RST) less than 50% of the central corneal thickness (CCT) was investigated from a biomechanical perspective.
Methods
Twelve rabbits were enrolled in this study, in which the right eye underwent SMILE surgery (the corneal cap thickness was one third of the preoperative CCT, approximately 120 µm), and the left eye served as the control. The rabbits were evenly divided into two groups, with the RST of 50% and 30% of the preoperative CCT in each group, respectively. Corneal morphology parameters in vivo and biomechanical properties in vitro were determined at 11 months after SMILE surgery. Moreover, the distribution of displacement and Von Mises stress across the cornea were evaluated using finite element analysis.
Results
At 11 months after SMILE surgery, there was no obvious forward shift in the posterior corneal elevation and no significant increase in the mean keratometry from the posterior corneal surface. The elastic modulus of the RST 30% group increased significantly compared to the control, although no significant differences were found in the creep rate, elongation rate, and equilibrium modulus among all groups. Compared to the control, the displacement was smaller in the RST 30% group, while the maximum stress was obviously higher.
Conclusions
No iatrogenic keratectasia occurred in a rabbit model of high myopic SMILE surgery with an RST of less than 50% of preoperative CCT at 11-month follow-up. Translational Relevance: Our findings could provide valuable insights into the safety of performing SMILE with reduced RST values for high myopia correction and guide SMILE procedures.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan, China.
- School of Ophthalmology, Shanxi Medical University, Taiyuan, China.
- College of Mechanical and Vehicle Engineering, Taiyuan University of Technology, Taiyuan, China.
Zitieren
APA
Qin, H., Yang, X., He, R., Song, Y., Wei, J., Liu, X., Wang, C., Wu, C., Hou, J., Gao, Z., Chen, L., Li, X., & Chen, W. (2025). Evaluation of the Long-Term Corneal Biomechanics Following SMILE With Different Residual Stromal Bed Thickness in Rabbits. Translational Vision Science & Technology. https://doi.org/10.1167/tvst.14.3.3
Vancouver
Qin H, Yang X, He R, Song Y, Wei J, Liu X, et al. Evaluation of the Long-Term Corneal Biomechanics Following SMILE With Different Residual Stromal Bed Thickness in Rabbits. Translational Vision Science & Technology. 2025. doi:10.1167/tvst.14.3.3
BibTeX
@article{Qin2025,
author = {Qin, Hongwei and Yang, Xin and He, Rui and Song, Yaowen and Wei, Junchao and Liu, Xiaona and Wang, Chenyan and Wu, Ce and Hou, Jie and Gao, Zhipeng and Chen, Lingfeng and Li, Xiaona and Chen, Weiyi},
title = {Evaluation of the Long-Term Corneal Biomechanics Following SMILE With Different Residual Stromal Bed Thickness in Rabbits},
journal = {Translational Vision Science & Technology},
year = {2025},
doi = {10.1167/tvst.14.3.3}
}