EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Automated Assessment of Choroidal Mass Dimensions Using Static and Dynamic Ultrasonographic Imaging

Noah Emmert, Gideon Wall, Amin Nabavi, Amir Rahdar, Matthew Wilson, Benjamin King, Linda Cernichiaro-Espinosa, Siamak Yousefi

Translational Vision Science & Technology · 2025

DOI: 10.1167/tvst.14.12.30 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Translational Vision Science & Technology, 2025. Verfasst von Noah Emmert und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, University of Tennessee Health Science Center, Memphis, TN, USA. Hauptthemen laut MEDLINE: Image Interpretation, Computer-Assisted, Ultrasonography, Choroid Neoplasms. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The purpose of this study was to develop and validate an artificial intelligence (AI) model for detecting and measuring choroidal mass dimensions on B-scan ophthalmic ultrasound images.

Methods

The study included 1822 still images and 130 cine loops of choroidal masses. For external validation, 180 additional still images were included, along with 374 control images to assess specificity. A two-stage U-Net-based architecture was trained to detect masses and measure dimensions. For cine loops, the algorithm automatically selected the frame with the largest mass cross-sectional area.

Results

In the internal subset, detection accuracy was 94.5% with a false-positive rate of 11.7%. For apical height, the mean absolute error (MAE) was 0.42 ± 0.58 mm (R² = 0.87), with 94.2% of cases within 1 mm of expert annotations. For basal diameter, the MAE was 1.02 ± 0.99 mm (R² = 0.74). In the external validation subset, detection accuracy was 83.9%, false-positive rate of 4.2%, and consistent millimeter-level precision for both apical height and basal diameter. Among cine loops, masses were detected in 99.2% of cases, with spatial awareness in 93.1%. Best-frame analysis yielded apical height within 1 mm of the reference in 68.2% of cases (MAE 1.10 ± 1.36 mm) and basal diameter with an MAE of 1.65 ± 1.84 mm.

Conclusions

Deep learning provides reproducible, millimeter-level measurements of choroidal mass dimensions from still images and cine loops, supporting its potential use for monitoring of choroidal tumors. Translational Relevance: AI can generate precise measurement of choroidal tumors, enabling clinically actionable monitoring from ophthalmic ultrasound.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Image Interpretation, Computer-AssistedUltrasonographyChoroid NeoplasmsHumansArtificial IntelligenceChoroidReproducibility of ResultsDetection AlgorithmsRetrospective StudiesCohort StudiesDeep LearningConvolutional Neural NetworksMaleFemaleMiddle AgedAged

Autor:innen und Institutionen

  • Department of Ophthalmology, University of Tennessee Health Science Center, Memphis, TN, USA.
  • The Department of Computer Science and Software Engineering, Miami University, Oxford, OH, USA.
  • Bascom Palmer Eye Institute, Department of Ophthalmology, University of Miami, Miami, FL, USA.
  • Chashmyar Startup, Tehran, Iran.
  • Department of Electrical and Computer Engineering, University of Miami, Miami, FL, USA.

Zitieren

APA

Emmert, N., Wall, G., Nabavi, A., Rahdar, A., Wilson, M., King, B., Cernichiaro-Espinosa, L., & Yousefi, S. (2025). Automated Assessment of Choroidal Mass Dimensions Using Static and Dynamic Ultrasonographic Imaging. Translational Vision Science & Technology. https://doi.org/10.1167/tvst.14.12.30

Vancouver

Emmert N, Wall G, Nabavi A, Rahdar A, Wilson M, King B, et al. Automated Assessment of Choroidal Mass Dimensions Using Static and Dynamic Ultrasonographic Imaging. Translational Vision Science & Technology. 2025. doi:10.1167/tvst.14.12.30

BibTeX
@article{Emmert2025,
  author = {Emmert, Noah and Wall, Gideon and Nabavi, Amin and Rahdar, Amir and Wilson, Matthew and King, Benjamin and Cernichiaro-Espinosa, Linda and Yousefi, Siamak},
  title = {Automated Assessment of Choroidal Mass Dimensions Using Static and Dynamic Ultrasonographic Imaging},
  journal = {Translational Vision Science & Technology},
  year = {2025},
  doi = {10.1167/tvst.14.12.30}
}
Kostenlos starten →