Transformer-Based Deep Learning Prediction of 10-Degree Humphrey Visual Field Tests From 24-Degree Data
Translational Vision Science & Technology · 2024
DOI: 10.1167/tvst.13.8.11 ↗Kurz gefasst
Fachartikel in der Zeitschrift Translational Vision Science & Technology, 2024. Verfasst von Min Shi und 15 weiteren Autor:innen. Beteiligte Einrichtung: Harvard Ophthalmology AI Lab, Schepens Eye Research Institute of Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA. Hauptthemen laut MEDLINE: Deep Learning, Visual Field Tests, Visual Fields, Glaucoma. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NEI NIH HHS.
Abstract (Originalsprache)
Purpose
To predict 10-2 Humphrey visual fields (VFs) from 24-2 VFs and associated non-total deviation features using deep learning.
Methods
We included 5189 reliable 24-2 and 10-2 VF pairs from 2236 patients, and 28,409 reliable pairs of macular OCT scans and 24-2 VF from 19,527 eyes of 11,560 patients. We developed a transformer-based deep learning model using 52 total deviation values and nine VF test features to predict 68 10-2 total deviation values. The mean absolute error, root mean square error, and the R2 were evaluation metrics. We further evaluated whether the predicted 10-2 VFs can improve the structure-function relationship between macular thinning and paracentral VF loss in glaucoma.
Results
The average mean absolute error and R2 for 68 10-2 VF test points were 3.30 ± 0.52 dB and 0.70 ± 0.11, respectively. The accuracy was lower in the inferior temporal region. The model placed greater emphasis on 24-2 VF points near the central fixation point when predicting the 10-2 VFs. The inclusion of nine VF test features improved the mean absolute error and R2 up to 0.17 ± 0.06 dB and 0.01 ± 0.01, respectively. Age was the most important 24-2 VF test parameter for 10-2 VF prediction. The predicted 10-2 VFs achieved an improved structure-function relationship between macular thinning and paracentral VF loss, with the R2 at the central 4, 12, and 16 locations of 24-2 VFs increased by 0.04, 0.05 and 0.05, respectively (P < 0.001).
Conclusions
The 10-2 VFs may be predicted from 24-2 data. Translational Relevance: The predicted 10-2 VF has the potential to improve glaucoma diagnosis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Harvard Ophthalmology AI Lab, Schepens Eye Research Institute of Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA.
- Massachusetts Eye and Ear, Harvard Medical School, Boston, MA, USA.
- Eye and Vision Research Institute, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
- Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA.
- Edward S. Harkness Eye Institute, Columbia University Medical Center, New York, NY, USA.
- Wills Eye Hospital, Thomas Jefferson University, Philadelphia, PA, USA.
Förderung
- NEI NIH HHS
Zitieren
APA
Shi, M., Lokhande, A., Tian, Y., Luo, Y., Eslami, M., Kazeminasab, S., Elze, T., Shen, L. Q., Pasquale, L. R., Wellik, S. R., De Moraes, C. G., Myers, J. S., Zebardast, N., Friedman, D. S., Boland, M. V., & Wang, M. (2024). Transformer-Based Deep Learning Prediction of 10-Degree Humphrey Visual Field Tests From 24-Degree Data. Translational Vision Science & Technology. https://doi.org/10.1167/tvst.13.8.11
Vancouver
Shi M, Lokhande A, Tian Y, Luo Y, Eslami M, Kazeminasab S, et al. Transformer-Based Deep Learning Prediction of 10-Degree Humphrey Visual Field Tests From 24-Degree Data. Translational Vision Science & Technology. 2024. doi:10.1167/tvst.13.8.11
BibTeX
@article{Shi2024,
author = {Shi, Min and Lokhande, Anagha and Tian, Yu and Luo, Yan and Eslami, Mohammad and Kazeminasab, Saber and Elze, Tobias and Shen, Lucy Q and Pasquale, Louis R and Wellik, Sarah R and De Moraes, Carlos Gustavo and Myers, Jonathan S and Zebardast, Nazlee and Friedman, David S and Boland, Michael V and Wang, Mengyu},
title = {Transformer-Based Deep Learning Prediction of 10-Degree Humphrey Visual Field Tests From 24-Degree Data},
journal = {Translational Vision Science & Technology},
year = {2024},
doi = {10.1167/tvst.13.8.11}
}
EUVIMED