EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieOpen Access · CC BY-NC-ND 4.0

The Impact of Back Optic Zone Design in Orthokeratology on Visual Performance

Xiaoqin Chen, Ying Guo, Hua Bi, Xuewei Liu, Yiyuan Wu, Ting Wang, Lihua Li, Wenli Lu, Maria Liu, Yan Wang

Translational Vision Science & Technology · 2024

DOI: 10.1167/tvst.13.5.12 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Translational Vision Science & Technology, 2024. Verfasst von Xiaoqin Chen und 9 weiteren Autor:innen. Beteiligte Einrichtung: Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China. Hauptthemen laut MEDLINE: Orthokeratologic Procedures, Visual Acuity, Myopia, Refraction, Ocular. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate the visual performance in adolescents undergoing orthokeratology (OrthoK) treatment with two different optical zone diameters (OZDs).

Methods

This randomized, double-masked, self-controlled prospective study was conducted at Tianjin Eye Hospital (Tianjin, China) in June 2022. Thirty-six eligible schoolchildren were enrolled and fitted with corneal refractive therapy lenses with two sizes of OZDs (5 mm [5OZ] and 6 mm [6OZ]). Each participant was randomized to wear the 5OZ in one eye and the 6OZ in the contralateral eye. Subjective visual quality was assessed using visual acuity, refraction, contrast sensitivity function, and visual symptoms, and the objective optical quality was assessed using ocular higher order aberrations (HOAs) and modulation transfer function (MTF).

Results

Thirty-five myopic children completed a 1-month follow-up visit. The 5OZ lens induced significantly smaller treatment zone diameters than the 6OZ lens (P < 0.001). Subjective visual quality did not differ significantly between the two groups. Compared to baseline, aberrations of Z40, coma-like, spherical-like, and total HOAs in both groups increased significantly (P < 0.05). For the 3-mm pupils, spherical aberration in the 5OZ group was significantly higher than that in the 6OZ group (P < 0.05). The MTF value of the 6OZ group was significantly higher than that of 5OZ group for 0.3 and 1.5 cycles per degree for the 3-mm pupils (P = 0.006 and P = 0.026, respectively). However, HOAs or MTF did not differ significantly between the two groups for the 5-mm pupils.

Conclusions

The difference induced by varying OZD was significant only in the smaller pupil condition. The selection of OZD in OrthoK designs in real-world patient management should be done while considering individual pupil size. Translational Relevance: This study revealed that the objective visual quality of small OZD lenses was only slightly affected for the small pupil size.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Orthokeratologic ProceduresVisual AcuityMyopiaRefraction, OcularHumansFemaleMaleProspective StudiesAdolescentChildDouble-Blind MethodContrast SensitivityContact Lenses

Autor:innen und Institutionen

  • Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China.
  • Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Eye Hospital, Tianjin, China.
  • Tianjin Eye Hospital Optometric Center, Tianjin, China.
  • College of Optometry, Nova Southeastern University, Davie, FL, USA.
  • Department of Epidemiology and Health Statistics, Tianjin Medical University, Tianjin, China.
  • School of Optometry, University of California, Berkeley, Berkeley, CA, USA.

Zitieren

APA

Chen, X., Guo, Y., Bi, H., Liu, X., Wu, Y., Wang, T., Li, L., Lu, W., Liu, M., & Wang, Y. (2024). The Impact of Back Optic Zone Design in Orthokeratology on Visual Performance. Translational Vision Science & Technology. https://doi.org/10.1167/tvst.13.5.12

Vancouver

Chen X, Guo Y, Bi H, Liu X, Wu Y, Wang T, et al. The Impact of Back Optic Zone Design in Orthokeratology on Visual Performance. Translational Vision Science & Technology. 2024. doi:10.1167/tvst.13.5.12

BibTeX
@article{Chen2024,
  author = {Chen, Xiaoqin and Guo, Ying and Bi, Hua and Liu, Xuewei and Wu, Yiyuan and Wang, Ting and Li, Lihua and Lu, Wenli and Liu, Maria and Wang, Yan},
  title = {The Impact of Back Optic Zone Design in Orthokeratology on Visual Performance},
  journal = {Translational Vision Science & Technology},
  year = {2024},
  doi = {10.1167/tvst.13.5.12}
}
Kostenlos starten →