Scotopic and Photopic Conventional Visual Acuity and Hyperacuity – Binocular Summation
Translational Vision Science & Technology · 19.04.2024 · 13 (4) · 25
DOI: 10.1167/tvst.13.4.25 ↗Kurz gefasst
Fachartikel in der Zeitschrift Translational Vision Science & Technology, erschienen am 19.04.2024. Verfasst von Sophie Korn und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Otto-von-Guericke-University, Magdeburg, Germany. Hauptthemen laut MEDLINE: Vision Tests, Vision, Binocular. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Purpose
The purpose of this study was to determine and compare binocular summation (BiS) of conventional visual acuity (cVA) versus hyperacuity (hVA) for photopic and scotopic luminance conditions as a potential biomarker to assess the outcome of interventions on binocular function.
Methods
Sixteen young adults (age range [years] = 21-31; 8 women; cVA logMAR < 0.0) participated in this study. The Freiburg Visual Acuity Test (FrACT) was used for VA testing and retested on another day. Both cVA and hVA were determined for dark grey optotypes on light grey background. Participants underwent 40 minutes of dark adaptation prior to scotopic VA testing. Binocular and monocular VA testing was performed. The eye with better VA over the 2 days of testing was selected, the BiS was quantified (binocular VA - better monocular VA) and repeated measures ANOVAs were performed.
Results
Binocular VA exceeded monocular VA for all luminance conditions, VA-types, and sessions. We report BiS estimates for photopic and scotopic cVA and hVA, (logMAR BiS ± SEM [decimal BiS]): photopic = -0.01 ± 0.01 [1.03] and -0.06 ± 0.03 [1.15]; and scotopic = -0.05 ± 0.01 [1.12] and -0.11 ± 0.04 [1.28], respectively). Improvement for binocular vision estimates ranged from 0.01 to 0.11 logMAR. A repeated-measures ANOVA (RM ANOVA) did not reveal significant effects of LUMINANCE or VA TYPE on BiS, albeit a trend for strongest BiS for scotopic hVA (15% vs. 28%, photopic versus scotopic, respectively) and weakest for photopic cVA (3% vs. 12%, photopic versus scotopic conditions, respectively).
Conclusions
Our results indicate that BiS of VA is relevant to scotopic and photopic hVA and cVA. It appears therefore a plausible candidate biomarker to assess the outcome of retinal therapies restoring rod or cone function on binocular vision. Translational Relevance: Binocular summation of visual acuity might serve as a clinical biomarker to monitor therapy outcome on binocular rod and cone-mediated vision.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Ophthalmology, Otto-von-Guericke-University, Magdeburg, Germany.
- Department of Ophthalmology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.
- Graduate School of Medical Sciences (Research School of Behavioural and Cognitive Neurosciences), University of Groningen, Groningen, The Netherlands.
- https://orcid.org/0000-0002-6921-5486.
- Eye Center, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany.
- https://orcid.org/0000-0003-2028-535X.
Zitieren
APA
Korn, S., Al-Nosairy, K. O., Gopiswaminathan, A. V., João, C., Scanferla, L., Bach, M., & Hoffmann, M. B. (2024). Scotopic and Photopic Conventional Visual Acuity and Hyperacuity – Binocular Summation. Translational Vision Science & Technology, 13(4), 25. https://doi.org/10.1167/tvst.13.4.25
Vancouver
Korn S, Al-Nosairy KO, Gopiswaminathan AV, João C, Scanferla L, Bach M, et al. Scotopic and Photopic Conventional Visual Acuity and Hyperacuity – Binocular Summation. Translational Vision Science & Technology. 2024;13(4):25. doi:10.1167/tvst.13.4.25
BibTeX
@article{Korn2024,
author = {Korn, Sophie and Al-Nosairy, Khaldoon O and Gopiswaminathan, Akshara V and João, Catarina and Scanferla, Lorenzo and Bach, Michael and Hoffmann, Michael B},
title = {Scotopic and Photopic Conventional Visual Acuity and Hyperacuity – Binocular Summation},
journal = {Translational Vision Science & Technology},
year = {2024},
volume = {13},
number = {4},
pages = {25},
doi = {10.1167/tvst.13.4.25}
}