Archetypal Analysis Reveals Consistent Visual Field Patterns for Stimulus Sizes III and V in Glaucoma and NAION
Translational Vision Science & Technology · 12.12.2024 · 13 (12) · 15
DOI: 10.1167/tvst.13.12.15 ↗Kurz gefasst
Fachartikel in der Zeitschrift Translational Vision Science & Technology, erschienen am 12.12.2024. Verfasst von David Szanto und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, Icahn School of Medicine at Mount Sinai, New York, NY, USA. Hauptthemen laut MEDLINE: Visual Fields, Visual Field Tests, Glaucoma, Optic Neuropathy, Ischemic. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NEI NIH HHS.
Abstract (Originalsprache)
Purpose
Disorders of the anterior optic nerve cause quantifiable patterns, or archetypes (AT), in visual fields (VFs) obtained using standardized automated perimetry using stimulus size III (size III). VFs with stimulus size V (size V) can reduce retest variability in eyes with moderate to severe loss. We postulated that VF testing using both stimuli would show similar ATs in eyes with glaucoma and nonarteritic anterior ischemic optic neuropathy (NAION).
Methods
We used 1969 same-day pairs of 24-2 size III and size V VFs from two datasets. QRK207 is the largest NAION study to date, and the VIPII study measured same-day VFs across many stimulus sizes. We censored raw sensitivities of less than 21 dB for size III and 24 dB for size V and age-standardized to total deviations, before archetypal analysis (AA). We compared the ATs between the two stimuli and the combined data.
Results
Using 14 ATs for both glaucoma and NAION, AA captured similar patterns between the two stimuli in both diseases with 87% of AT pairings having a cosine similarity of 0.8 or greater. The combined ATs retained the patterns in the separate stimuli VFs.
Conclusions
AA shows that size V VFs provide quantifiable patterns of loss similar to size III. This aids in comparing stimulus sizes for monitoring VF patterns in disease progression. Translational Relevance: AA shows similar quantifiable patterns of VF loss with size III or size V, supporting the use of size V to monitor eyes with moderate to severe VF loss.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Neurology, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
- Department of Ophthalmology and Visual Sciences, University of Iowa, Iowa City, IA, USA.
- School of Medicine, Deakin University, Geelong, Australia.
- Irish Clinical Academic Training Programme, Department of Ophthalmology, Galway University Hospital, Galway, Ireland, UK.
- Schepens Eye Research Institute, Harvard Medical School, Boston, MA, USA.
- Center for the Prevention and Treatment of Visual Loss, Iowa City VA Health System, Iowa City, IA, USA.
Förderung
- NEI NIH HHS
Zitieren
APA
Szanto, D., Wall, M., Chong, L. X., Woods, B., Elze, T., Wang, J. K., Garvin, M., Kardon, R., & Kupersmith, M. J. (2024). Archetypal Analysis Reveals Consistent Visual Field Patterns for Stimulus Sizes III and V in Glaucoma and NAION. Translational Vision Science & Technology, 13(12), 15. https://doi.org/10.1167/tvst.13.12.15
Vancouver
Szanto D, Wall M, Chong LX, Woods B, Elze T, Wang JK, et al. Archetypal Analysis Reveals Consistent Visual Field Patterns for Stimulus Sizes III and V in Glaucoma and NAION. Translational Vision Science & Technology. 2024;13(12):15. doi:10.1167/tvst.13.12.15
BibTeX
@article{Szanto2024,
author = {Szanto, David and Wall, Michael and Chong, Luke X and Woods, Brian and Elze, Tobias and Wang, Jui-Kai and Garvin, Mona and Kardon, Randy and Kupersmith, Mark J},
title = {Archetypal Analysis Reveals Consistent Visual Field Patterns for Stimulus Sizes III and V in Glaucoma and NAION},
journal = {Translational Vision Science & Technology},
year = {2024},
volume = {13},
number = {12},
pages = {15},
doi = {10.1167/tvst.13.12.15}
}