EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC-ND 4.0

Comparison of Geographic Atrophy Measurements Between Blue-Light Heidelberg Standard Field and Green-Light Optos Ultrawide Field Autofluorescence

Colin P Froines, Thomas F Saunders, Jennifer A Heathcote, Jeong W Pak, Emily Y Chew, Barbara A Blodi, Amitha Domalpally

Translational Vision Science & Technology · 2024

DOI: 10.1167/tvst.13.11.1 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Translational Vision Science & Technology, 2024. Verfasst von Colin P Froines und 6 weiteren Autor:innen. Beteiligte Einrichtung: Wisconsin Reading Center, Department of Ophthalmology and Visual Sciences, University of Wisconsin School of Medicine and Public Health, Madison, WI,…. Hauptthemen laut MEDLINE: Geographic Atrophy, Optical Imaging. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study compared geographic atrophy (GA) measurements in the macula using standard 30° field and ultrawide field (UWF) fundus autofluorescence (FAF) imaging.

Methods

Participants from Age-Related Eye Disease Study 2 (AREDS2) and Optos PEripheral RetinA (OPERA) studies with GA were included for comparison between standard field FAF with Heidelberg Spectralis and Optos 200Tx UWF FAF. Two time points 5 years apart were evaluated. GA area (mm2) was recorded in the macular area for both imaging types and in the peripheral field for UWF.

Results

Of 102 paired images (73 subjects), the mean (SD) baseline GA area was 5.32 (6.36) mm2 with standard and 4.79 (5.87) mm2 with UWF FAF (P < 0.001). The mean difference between the two modalities was 0.52 mm2 (95% confidence interval, -2.41 to 1.37). Progression of GA in 25 eyes over 5 years showed a median annual growth rate of 1.28 mm2 (range, 0.02 to 4.7) for standard and 1.34 mm2 (range, 0.04 to 5.3) for UWF FAF (P = 0.49).

Conclusions

The measurement of GA is larger on standard than on UWF FAF imaging. The observed difference may be due to image averaging and the use of blue versus green FAF. Similar GA progression with standard and UWF FAF suggests either may be used longitudinally, although not interchangeably. Further investigation is required with updated UWF technology. Translational Relevance: With the increasing adoption of UWF imaging modalities, this study suggests that Optos UWF FAF may be used longitudinally as an alternative to standard field FAF to monitor GA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Geographic AtrophyOptical ImagingHumansFemaleMaleAgedFluorescein AngiographyAged, 80 and overMiddle AgedDisease ProgressionFundus Oculi

Autor:innen und Institutionen

  • Wisconsin Reading Center, Department of Ophthalmology and Visual Sciences, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA.
  • Division of Epidemiology and Clinical Applications, National Eye Institute, Bethesda, MD, USA.

Zitieren

APA

Froines, C. P., Saunders, T. F., Heathcote, J. A., Pak, J. W., Chew, E. Y., Blodi, B. A., & Domalpally, A. (2024). Comparison of Geographic Atrophy Measurements Between Blue-Light Heidelberg Standard Field and Green-Light Optos Ultrawide Field Autofluorescence. Translational Vision Science & Technology. https://doi.org/10.1167/tvst.13.11.1

Vancouver

Froines CP, Saunders TF, Heathcote JA, Pak JW, Chew EY, Blodi BA, et al. Comparison of Geographic Atrophy Measurements Between Blue-Light Heidelberg Standard Field and Green-Light Optos Ultrawide Field Autofluorescence. Translational Vision Science & Technology. 2024. doi:10.1167/tvst.13.11.1

BibTeX
@article{Froines2024,
  author = {Froines, Colin P and Saunders, Thomas F and Heathcote, Jennifer A and Pak, Jeong W and Chew, Emily Y and Blodi, Barbara A and Domalpally, Amitha},
  title = {Comparison of Geographic Atrophy Measurements Between Blue-Light Heidelberg Standard Field and Green-Light Optos Ultrawide Field Autofluorescence},
  journal = {Translational Vision Science & Technology},
  year = {2024},
  doi = {10.1167/tvst.13.11.1}
}
Kostenlos starten →