A New Intraocular Lens Power Formula Integrating an Artificial Intelligence–Powered Estimation for Effective Lens Position Based on Chinese Eyes

Wei Lou, Wanru Zhou, Mingxing Wu, Haiying Jin

Translational Vision Science & Technology · 30.10.2024 · 13 (10) · 40

DOI: 10.1167/tvst.13.10.40 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Translational Vision Science & Technology, erschienen am 30.10.2024. Verfasst von Wei Lou und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Shanghai East Hospital, Tongji University School of Medicine, Tongji University, Shanghai, China. Hauptthemen laut MEDLINE: Algorithms, Artificial Intelligence, Lenses, Intraocular. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To develop and evaluate a new intraocular lens (IOL) formula based on Chinese eyes.

Methods

A training dataset of 709 eyes undergoing uneventful cataract surgery was used to train the algorithm for effective lens position estimation. The algorithm was then integrated with Gaussian optics to develop the new IOL formula (Jin-AI). From the same center, 177 eyes served as an internal test dataset. An independent dataset of 557 eyes served as an external test dataset. The standard deviation (SD) of prediction errors was compared among the Jin-AI formula, traditional third-generation formulas (SRK/T, Holladay 1, Hoffer Q), and newer generation formulas (Kane, Barrett Universal II [BUII], Hill-radial basis function [RBF] 3.0, and PEARL-DGS).

Results

In the internal test dataset, the Jin-AI formula showed the lowest SD (0.25 D), followed by the BUII (0.31 D), Kane (0.33 D), and PEARL-DGS (0.33 D) formulas. In the external test dataset, the Jin-AI, Kane, and PEARL-DGS formulas had the lowest SD (0.38 D), followed by the BUII (0.39 D), Hill-RBF 3.0 (0.39 D), SRK/T (0.45 D), Holladay 1 (0.48 D), and Hoffer Q (0.48 D) formulas. The SD of the Jin-AI formula was significantly lower than the third-generation formulas and comparable to the four newer generation formulas. Predictive accuracy of the Jin-AI formula was similar to the newer generation formulas across all axial length, keratometry, and anterior chamber depth ranges.

Conclusions

The new formula has exhibited good performance in predicting postoperative refractions. Its overall predictive accuracy was better than the third-generation formulas and comparable to the newer generation ones. Translational Relevance: The Jin-AI formula could be a reliable alternative for IOL power calculation in Chinese.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AlgorithmsArtificial IntelligenceLenses, IntraocularAgedAged, 80 and overFemaleHumansMaleMiddle AgedBiometryCataract ExtractionChinaEast Asian PeopleLens Implantation, IntraocularOptics and PhotonicsPhacoemulsificationRefraction, OcularVisual Acuity

Autor:innen und Institutionen

  • Department of Ophthalmology, Shanghai East Hospital, Tongji University School of Medicine, Tongji University, Shanghai, China.
  • State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-Sen University, Guangzhou, China.

Zitieren

APA

Lou, W., Zhou, W., Wu, M., & Jin, H. (2024). A New Intraocular Lens Power Formula Integrating an Artificial Intelligence–Powered Estimation for Effective Lens Position Based on Chinese Eyes. Translational Vision Science & Technology, 13(10), 40. https://doi.org/10.1167/tvst.13.10.40

Vancouver

Lou W, Zhou W, Wu M, Jin H. A New Intraocular Lens Power Formula Integrating an Artificial Intelligence–Powered Estimation for Effective Lens Position Based on Chinese Eyes. Translational Vision Science & Technology. 2024;13(10):40. doi:10.1167/tvst.13.10.40

BibTeX
@article{Lou2024,
  author = {Lou, Wei and Zhou, Wanru and Wu, Mingxing and Jin, Haiying},
  title = {A New Intraocular Lens Power Formula Integrating an Artificial Intelligence–Powered Estimation for Effective Lens Position Based on Chinese Eyes},
  journal = {Translational Vision Science & Technology},
  year = {2024},
  volume = {13},
  number = {10},
  pages = {40},
  doi = {10.1167/tvst.13.10.40}
}