Deep Learning Identifies High-Quality Fundus Photographs and Increases Accuracy in Automated Primary Open Angle Glaucoma Detection
Translational Vision Science & Technology · 29.01.2024 · 13 (1) · 23
DOI: 10.1167/tvst.13.1.23 ↗Kurz gefasst
Fachartikel in der Zeitschrift Translational Vision Science & Technology, erschienen am 29.01.2024. Verfasst von Benton Chuter und 13 weiteren Autor:innen. Beteiligte Einrichtung: Hamilton Glaucoma Center, Shiley Eye Institute, Viterbi Family Department of Ophthalmology, UC San Diego, La Jolla, California, United States. Hauptthemen laut MEDLINE: Deep Learning, Glaucoma, Open-Angle, Glaucoma, Ocular Hypertension. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NEI NIH HHS.
Abstract (Originalsprache)
Purpose
To develop and evaluate a deep learning (DL) model to assess fundus photograph quality, and quantitatively measure its impact on automated POAG detection in independent study populations.
Methods
Image quality ground truth was determined by manual review of 2815 fundus photographs of healthy and POAG eyes from the Diagnostic Innovations in Glaucoma Study and African Descent and Glaucoma Evaluation Study (DIGS/ADAGES), as well as 11,350 from the Ocular Hypertension Treatment Study (OHTS). Human experts assessed a photograph as high quality if of sufficient quality to determine POAG status and poor quality if not. A DL quality model was trained on photographs from DIGS/ADAGES and tested on OHTS. The effect of DL quality assessment on DL POAG detection was measured using area under the receiver operating characteristic (AUROC).
Results
The DL quality model yielded an AUROC of 0.97 for differentiating between high- and low-quality photographs; qualitative human review affirmed high model performance. Diagnostic accuracy of the DL POAG model was significantly greater (P < 0.001) in good (AUROC, 0.87; 95% CI, 0.80-0.92) compared with poor quality photographs (AUROC, 0.77; 95% CI, 0.67-0.88).
Conclusions
The DL quality model was able to accurately assess fundus photograph quality. Using automated quality assessment to filter out low-quality photographs increased the accuracy of a DL POAG detection model. Translational Relevance: Incorporating DL quality assessment into automated review of fundus photographs can help to decrease the burden of manual review and improve accuracy for automated DL POAG detection.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Hamilton Glaucoma Center, Shiley Eye Institute, Viterbi Family Department of Ophthalmology, UC San Diego, La Jolla, California, United States.
- Department of Ophthalmology, University Medical Center Mainz, Germany.
- School of Medicine, Callahan Eye Hospital, University of Alabama-Birmingham, Birmingham, Alabama, United States.
- Bernard and Shirlee Brown Glaucoma Research Laboratory, Edward S. Harkness Eye Institute, Department of Ophthalmology, Columbia University Medical Center, New York, New York, United States.
Förderung
- NEI NIH HHS
Zitieren
APA
Chuter, B., Huynh, J., Bowd, C., Walker, E., Rezapour, J., Brye, N., Belghith, A., Fazio, M. A., Girkin, C. A., De Moraes, G., Liebmann, J. M., Weinreb, R. N., Zangwill, L. M., & Christopher, M. (2024). Deep Learning Identifies High-Quality Fundus Photographs and Increases Accuracy in Automated Primary Open Angle Glaucoma Detection. Translational Vision Science & Technology, 13(1), 23. https://doi.org/10.1167/tvst.13.1.23
Vancouver
Chuter B, Huynh J, Bowd C, Walker E, Rezapour J, Brye N, et al. Deep Learning Identifies High-Quality Fundus Photographs and Increases Accuracy in Automated Primary Open Angle Glaucoma Detection. Translational Vision Science & Technology. 2024;13(1):23. doi:10.1167/tvst.13.1.23
BibTeX
@article{Chuter2024,
author = {Chuter, Benton and Huynh, Justin and Bowd, Christopher and Walker, Evan and Rezapour, Jasmin and Brye, Nicole and Belghith, Akram and Fazio, Massimo A and Girkin, Christopher A and De Moraes, Gustavo and Liebmann, Jeffrey M and Weinreb, Robert N and Zangwill, Linda M and Christopher, Mark},
title = {Deep Learning Identifies High-Quality Fundus Photographs and Increases Accuracy in Automated Primary Open Angle Glaucoma Detection},
journal = {Translational Vision Science & Technology},
year = {2024},
volume = {13},
number = {1},
pages = {23},
doi = {10.1167/tvst.13.1.23}
}
EUVIMED