EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Noncontact Acoustic Micro-Tapping Optical Coherence Elastography for Quantification of Corneal Anisotropic Elasticity: In Vivo Rabbit Study

Mitchell A Kirby, Gabriel Regnault, Ivan Pelivanov, Matthew O'Donnell, Ruikang K Wang, Tueng T Shen

Translational Vision Science & Technology · 2023

DOI: 10.1167/tvst.12.3.15 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Translational Vision Science & Technology, 2023. Verfasst von Mitchell A Kirby und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Bioengineering, University of Washington, Seattle, WA, USA. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NEI NIH HHS, NCI NIH HHS, NIAMS NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The purpose of this study was to demonstrate accurate measurement of corneal elastic moduli in vivo with noncontact and noninvasive optical coherence elastography.

Methods

Elastic properties (in-plane Young's modulus, E, and both in-plane, μ, and out-of-plane, G, shear moduli) of rabbit cornea were quantified in vivo using noncontact dynamic acoustic micro-tapping optical coherence elastography (AµT-OCE). The intraocular pressure (IOP)-dependence of measured mechanical properties was explored in extracted whole globes following in vivo measurement. A nearly incompressible transverse isotropic (NITI) model was used to reconstruct moduli from AµT-OCE data. Independently, cornea elastic moduli were also measured ex vivo with traditional, destructive mechanical tests (tensile extensometry and shear rheometry).

Results

Our study demonstrates strong anisotropy of corneal elasticity in rabbits. The in-plane Young's modulus, computed as E = 3μ, was in the range of 20 MPa to 44 MPa, whereas the out-of-plane shear modulus was in the range of 34 kPa to 261 kPa. Both pressure-dependent ex vivo OCE and destructive mechanical tests performed on the same samples within an hour of euthanasia strongly support the results of AµT-OCE measurements.

Conclusions

Noncontact AµT-OCE can noninvasively quantify cornea anisotropic elastic properties in vivo. Translational Relevance: As optical coherence tomography (OCT) is broadly accepted in ophthalmology, these results suggest the potential for rapid translation of AµT-OCE into clinical practice. In addition, AµT-OCE can likely improve diagnostic criteria of ectatic corneal diseases, leading to early diagnosis, reduced complications, customized surgical treatment, and personalized biomechanical models of the eye.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Elasticity Imaging TechniquesAnimalsRabbitsAnisotropyElasticityCorneaAcoustics

Autor:innen und Institutionen

  • Department of Bioengineering, University of Washington, Seattle, WA, USA.
  • Department of Ophthalmology, University of Washington, Seattle, WA, USA.
  • School of Medicine, University of Washington, Seattle, WA, USA.

Förderung

  • NEI NIH HHS
  • NCI NIH HHS
  • NIAMS NIH HHS
  • NIBIB NIH HHS

Zitieren

APA

Kirby, M. A., Regnault, G., Pelivanov, I., O'Donnell, M., Wang, R. K., & Shen, T. T. (2023). Noncontact Acoustic Micro-Tapping Optical Coherence Elastography for Quantification of Corneal Anisotropic Elasticity: In Vivo Rabbit Study. Translational Vision Science & Technology. https://doi.org/10.1167/tvst.12.3.15

Vancouver

Kirby MA, Regnault G, Pelivanov I, O'Donnell M, Wang RK, Shen TT. Noncontact Acoustic Micro-Tapping Optical Coherence Elastography for Quantification of Corneal Anisotropic Elasticity: In Vivo Rabbit Study. Translational Vision Science & Technology. 2023. doi:10.1167/tvst.12.3.15

BibTeX
@article{Kirby2023,
  author = {Kirby, Mitchell A and Regnault, Gabriel and Pelivanov, Ivan and O'Donnell, Matthew and Wang, Ruikang K and Shen, Tueng T},
  title = {Noncontact Acoustic Micro-Tapping Optical Coherence Elastography for Quantification of Corneal Anisotropic Elasticity: In Vivo Rabbit Study},
  journal = {Translational Vision Science & Technology},
  year = {2023},
  doi = {10.1167/tvst.12.3.15}
}
Kostenlos starten →