EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Impact of Single Constant Optimization on the Precision of IOL Power Calculation

Damien Gatinel, Guillaume Debellemanière, Alain Saad, Avi Wallerstein, Mathieu Gauvin, Radhika Rampat, Jacques Malet

Translational Vision Science & Technology · 06.11.2023 · 12 (11) · 11

DOI: 10.1167/tvst.12.11.11 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Translational Vision Science & Technology, erschienen am 06.11.2023. Verfasst von Damien Gatinel und 6 weiteren Autor:innen. Beteiligte Einrichtung: Anterior Segment and Refractive Surgery Department, Rothschild Foundation Hospital, Paris, France. Hauptthemen laut MEDLINE: Cataract, Lenses, Intraocular. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The primary objective of this research is to examine how precision in intraocular lens calculation formulas can be impacted by zeroing the mean error through adjustments in the effective lens position value. Additionally, the study aims to evaluate how this modification influences outcomes differently based on the source of the prediction error.

Methods

In order to analyze the impact of individual variables on the standard deviation, the study maintained all variables constant except for one at a time. Subsequently, variations were introduced to specific parameters, such as corneal curvature radius, keratometric refractive index, axial length, and predicted implant position.

Results

According to our findings, when zeroing the mean error is applied to correct for inaccuracies in corneal power estimation, it results in a significant and exponential rise in standard deviation, thus adversely affecting the formula's precision. However, when zeroing is employed to compensate for prediction errors stemming from axial length measurements or predicted implant position, the effect on precision is minimal or potentially beneficial.

Conclusions

The study highlights the potential risks associated with the indiscriminate but necessary zeroing of prediction errors in implant power calculation formulas. The impact on formula precision greatly depends on the source of the error, underscoring the importance of error source when analyzing variations in the standard deviation of the prediction error after zeroing. Translational Relevance: Our study contributes to the ongoing effort to enhance the accuracy and reliability of these formulas, thereby improving the surgical outcomes for cataract patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CataractLenses, IntraocularHumansReproducibility of ResultsCornea

Autor:innen und Institutionen

  • Anterior Segment and Refractive Surgery Department, Rothschild Foundation Hospital, Paris, France.
  • Department of Ophthalmology and Visual Sciences, McGill University, Montreal, QC, Canada.
  • LASIK MD, Montreal, QC, Canada.

Zitieren

APA

Gatinel, D., Debellemanière, G., Saad, A., Wallerstein, A., Gauvin, M., Rampat, R., & Malet, J. (2023). Impact of Single Constant Optimization on the Precision of IOL Power Calculation. Translational Vision Science & Technology, 12(11), 11. https://doi.org/10.1167/tvst.12.11.11

Vancouver

Gatinel D, Debellemanière G, Saad A, Wallerstein A, Gauvin M, Rampat R, et al. Impact of Single Constant Optimization on the Precision of IOL Power Calculation. Translational Vision Science & Technology. 2023;12(11):11. doi:10.1167/tvst.12.11.11

BibTeX
@article{Gatinel2023,
  author = {Gatinel, Damien and Debellemanière, Guillaume and Saad, Alain and Wallerstein, Avi and Gauvin, Mathieu and Rampat, Radhika and Malet, Jacques},
  title = {Impact of Single Constant Optimization on the Precision of IOL Power Calculation},
  journal = {Translational Vision Science & Technology},
  year = {2023},
  volume = {12},
  number = {11},
  pages = {11},
  doi = {10.1167/tvst.12.11.11}
}
Kostenlos starten →