EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Magnetic Resonance Dacryocystography for Precise Diagnosis of Lacrimal and Perilacrimal Lesions

Xuejun Guo, Min Gao, Yulong Qi, Qiao Shi, Qiqiang Li, Mingmei Li, Hongbing Li

Investigative Ophthalmology & Visual Science · 2025

DOI: 10.1167/iovs.66.3.17 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Investigative Ophthalmology & Visual Science, 2025. Verfasst von Xuejun Guo und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Peking University Shenzhen Hospital, Shenzhen, Guangdong, China. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Lacrimal Duct Obstruction, Nasolacrimal Duct, Lacrimal Apparatus Diseases. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The accurate determination of the etiology and location of lacrimal passage obstruction is key to treatment. However, the main assessments for lacrimal passage are invasive and have limited value. This study aimed to analyze the causes of obstruction of the lacrimal passage and investigate the diagnostic value of magnetic resonance dacryocystography (MRD).

Methods

Fifty-six patients (69 eyes) with lacrimal disease underwent MRD after lacrimal irrigation. The stenotic site and degree were determined. The accuracies of the diagnoses of lesions at different sites based on MRD and routine clinical assessment were determined and compared, and a noninferiority test was used to verify the values obtained via MRD.

Results

The lesion location determined through lacrimal irrigation was inconsistent with that determined through MRD. The overall accuracy of routine clinical assessment was approximately 79.7% (55 of 69) and that of MRD reached 98.6% (68 of 69). For the lesion location, the clinical misdiagnosis rates were 38.9%, 43.8%, and 63.6% for the lacrimal sac, nasolacrimal duct, and perilacrimal passage, respectively. The MRD and surgical pathology results for the lacrimal sac, nasolacrimal duct, and perilacrimal passage were consistent, except for the lacrimal canaliculus. The P value for the noninferiority of MRD to surgical pathology was 0.32.

Conclusions

MRD is noninvasive and has high value for determining the cause, location, and degree of lacrimal stenosis. Its findings are nearly as accurate as those of surgical pathology. MRD should be recommended over other invasive methods for evaluating lacrimal and prelacrimal lesions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingLacrimal Duct ObstructionNasolacrimal DuctLacrimal Apparatus DiseasesLacrimal ApparatusHumansMaleFemaleMiddle AgedAdultAgedYoung AdultAdolescentRetrospective StudiesAged, 80 and overChild

Autor:innen und Institutionen

  • Department of Radiology, Peking University Shenzhen Hospital, Shenzhen, Guangdong, China.
  • Department of Nephrology, Peking University Shenzhen Hospital, Shenzhen, Guangdong, China.
  • Department of General Practice, Fuyong People's Hospital, Baoan District, Shenzhen, Guangdong, China.
  • Department of Radiology, Fuyong People's Hospital, Baoan District, Shenzhen, Guangdong, China.

Zitieren

APA

Guo, X., Gao, M., Qi, Y., Shi, Q., Li, Q., Li, M., & Li, H. (2025). Magnetic Resonance Dacryocystography for Precise Diagnosis of Lacrimal and Perilacrimal Lesions. Investigative Ophthalmology & Visual Science. https://doi.org/10.1167/iovs.66.3.17

Vancouver

Guo X, Gao M, Qi Y, Shi Q, Li Q, Li M, et al. Magnetic Resonance Dacryocystography for Precise Diagnosis of Lacrimal and Perilacrimal Lesions. Investigative Ophthalmology & Visual Science. 2025. doi:10.1167/iovs.66.3.17

BibTeX
@article{Guo2025,
  author = {Guo, Xuejun and Gao, Min and Qi, Yulong and Shi, Qiao and Li, Qiqiang and Li, Mingmei and Li, Hongbing},
  title = {Magnetic Resonance Dacryocystography for Precise Diagnosis of Lacrimal and Perilacrimal Lesions},
  journal = {Investigative Ophthalmology & Visual Science},
  year = {2025},
  doi = {10.1167/iovs.66.3.17}
}
Kostenlos starten →