Accelerated Neutral Atom Beam (ANAB) Modified Poly-Ether-Ether-Ketone for Increasing In Vitro Bone Cell Functions and Reducing Bacteria Colonization Without Drugs or Antibiotics
Journal of Biomedical Nanotechnology · 01.03.2022 · 18 (3) · 788-795
DOI: 10.1166/jbn.2022.3247 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Biomedical Nanotechnology, erschienen am 01.03.2022. Verfasst von Thomas J Webster und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical Engineering, Northeastern University, Boston, MA 02115, USA. Hauptthemen laut MEDLINE: Ether, Ketones. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 23 Literaturangaben.
Abstract (Originalsprache)
Poly-ether-ether-ketone (PEEK) has become the spinal implant material of choice due to its radiolucency, low elastic modulus, manufacturability, and mechanical durability. However, studies have highlighted less that optimal cytocompatibility properties of conventional PEEK leading to decreased bone growth and/or extensive bacteria infection. In order to improve the surface properties of PEEK for orthopedic applications, here, Accelerated Neutral Atom Beam (ANAB) technology was used to modify PEEK and such samples were tested In Vitro for osteoblast (bone-forming cell) functions and bacterial colonization. Results showed significantly improved osteoblast responses (such as deposition of calcium containing mineral as well as alkaline phosphatase, osteocalcin, osteopontin, and osteonectin synthesis) on ANAB modified PEEK compared to controls due to optimized surface energy from nanostructured features and greater exposure of PEEK chemistry. ANAB treatment enhanced protein absorption (specifically, mucin, casein, and lubricin) to the PEEK surface and consequently significantly reduced bacterial (including methicillin resistant Staph. aureus (or MRSA), E. coli , and Staph. epidermidis ) colonization. Collectively, this study introduces ANAB treated PEEK as a novel material that should be further studied for a wide range of improved orthopedic applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Chemical Engineering, Northeastern University, Boston, MA 02115, USA.
- Materials Characterization Laboratory, Pennsylvania State University, University Park, PA 16802, USA.
- Institute for Medical Engineering and Science, Massachusetts Institute of Technology, Cambridge MA 02139 and Division of Cardiovascular Medicine, Brigham and Women's Hospital and Harvard Medical School, Boston MA 02115,…
- Vallum Corporation, Nashua, NH 03060, USA.
Zitieren
APA
Webster, T. J., Shallenberger, J. R., Edelman, E. R., & Khoury, J. (2022). Accelerated Neutral Atom Beam (ANAB) Modified Poly-Ether-Ether-Ketone for Increasing In Vitro Bone Cell Functions and Reducing Bacteria Colonization Without Drugs or Antibiotics. Journal of Biomedical Nanotechnology, 18(3), 788-795. https://doi.org/10.1166/jbn.2022.3247
Vancouver
Webster TJ, Shallenberger JR, Edelman ER, Khoury J. Accelerated Neutral Atom Beam (ANAB) Modified Poly-Ether-Ether-Ketone for Increasing In Vitro Bone Cell Functions and Reducing Bacteria Colonization Without Drugs or Antibiotics. Journal of Biomedical Nanotechnology. 2022;18(3):788-795. doi:10.1166/jbn.2022.3247
BibTeX
@article{Webster2022,
author = {Webster, Thomas J and Shallenberger, Jeffrey R and Edelman, Elazer R and Khoury, Joseph},
title = {Accelerated Neutral Atom Beam (ANAB) Modified Poly-Ether-Ether-Ketone for Increasing In Vitro Bone Cell Functions and Reducing Bacteria Colonization Without Drugs or Antibiotics},
journal = {Journal of Biomedical Nanotechnology},
year = {2022},
volume = {18},
number = {3},
pages = {788--795},
doi = {10.1166/jbn.2022.3247}
}
EUVIMED