Fire Behavior of Timber-Encased Steel Composite Structures: A Meta-Analytic Review of Experimental Findings and Design Implications
Research and Innovation · 19.12.2025 · 1 (1) · 71-76
DOI: 10.11648/j.ri.20250101.19 ↗Kurz gefasst
Fachartikel in der Zeitschrift Research and Innovation, online erschienen am 19.12.2025. Verfasst von Girmay Aznaw. Die Arbeit nennt 15 Literaturangaben.
Abstract (Originalsprache)
Timber-encased steel composite (TESC) systems have emerged as a promising structural solution combining strength, sustainability, and enhanced fire performance. This meta-analytic review synthesizes experimental and numerical findings reported between 2020 and 2025 to assess the influence of timber encasement on the fire resistance of steel members. Data from full-scale and small-scale fire tests were statistically aggregated using random-effects models to determine pooled fire resistance and to quantify the effects of parameters such as timber thickness and moisture content. Results show that full timber encasement markedly delays steel heating and improves fire endurance. On average, each additional millimeter of timber cover contributes approximately 1.9 minutes of fire resistance (p < 0.01), with 50 mm encasement achieving roughly one hour of protection under ISO 834 conditions. Moisture within the timber further reduces the rate of temperature rise by absorbing latent heat during evaporation. The study confirms that the insulating and charring behavior of timber functions as an effective passive fire-protection layer, offering an alternative to conventional coatings or boards. Design implications are significant: empirical correlations between cover thickness and fire resistance can inform future fire-design models and code calibrations. Remaining research needs include long-term performance of composite joints and validation under realistic fire scenarios. Overall, the review provides quantitative evidence supporting timber encasement as a viable, sustainable, and code-integral approach for improving the fire safety of composite steel structures.
Zitieren
APA
Aznaw, G. (2025). Fire Behavior of Timber-Encased Steel Composite Structures: A Meta-Analytic Review of Experimental Findings and Design Implications. Research and Innovation, 1(1), 71-76. https://doi.org/10.11648/j.ri.20250101.19
Vancouver
Aznaw G. Fire Behavior of Timber-Encased Steel Composite Structures: A Meta-Analytic Review of Experimental Findings and Design Implications. Research and Innovation. 2025;1(1):71-76. doi:10.11648/j.ri.20250101.19
BibTeX
@article{Aznaw2025,
author = {Aznaw, Girmay},
title = {Fire Behavior of Timber-Encased Steel Composite Structures: A Meta-Analytic Review of Experimental Findings and Design Implications},
journal = {Research and Innovation},
year = {2025},
volume = {1},
number = {1},
pages = {71--76},
doi = {10.11648/j.ri.20250101.19}
}