EUVIMEDEUVIMED entdecken
Crossref

Reliability of Transthoracic Echocardiography to Guide Transcatheter Closure of Atrial Septal Defects

Sadiq Al-Hamash, Khalid Ahmed Khalid, Omar Zidane Khalaf

Pathology and Laboratory Medicine · 05.11.2021 · 5 (2) · 38-42

DOI: 10.11648/j.plm.20210502.14 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pathology and Laboratory Medicine, online erschienen am 05.11.2021. Verfasst von Sadiq Al-Hamash und 2 weiteren Autor:innen. Die Arbeit nennt 20 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Transthoracic echocardiography (TTE) is used for the pre-interventional assessment of atrial septal defects (ASDs). However, the efficacy of TTE for guiding transcatheter closure of ASD still has not been widely assessed. The aim of this study was to evaluate the efficacy, and reliability of TTE in pre selecting ASDs for transcatheter closure using the Occlutech Figulla ASD occluder. Patients & methods: This was a prospective study carried out between April 1, 2019 and February 1, 2020. Forty-nine patients were referred for transcatheter closure of their ASDs at mean age of 22±18 years and mean weight of 36±17 kg. TTE was used to measure the largest ASD diameter in different views. The device diameter used for closure was chosen based on the largest diameter obtained by TTE plus 3-5 mm if ASD < 20 mm, and 5-6 mm if ASD > 20 mm.

Results

The patients divided into two groups according to the size of ASD, group A when the size of the defect was < 20 mm, and group B when the size of the defect was > 20 mm. The average size of the defects for group A 16±4 mm, and 28±6mm for group B. the average size of the devices used was 19±5mm, and 33±7 mm for group A and B respectively. Transcatheter closure of ASD was successful in 41 patients (83.6%), and failed in 8 patients (16.4%). In 7 out of the 8 failed cases, the closure was achieved successfully using transesophageal echocardiography (TEE) guidance and one patient, was referred for surgical closure due to an acute complication due to large pericardial effusion and tamponade that resulted from injury to the left atrial appendage. The successful rate for selection of the appropriate ASD device was 83.6%. Conclusion: this study demonstrated that TTE is satisfactory & reliable in selecting the appropriate ASD device size & in guiding transcatheter closure of ASD.

Zitieren

APA

Al-Hamash, S., Khalid, K. A., & Khalaf, O. Z. (2021). Reliability of Transthoracic Echocardiography to Guide Transcatheter Closure of Atrial Septal Defects. Pathology and Laboratory Medicine, 5(2), 38-42. https://doi.org/10.11648/j.plm.20210502.14

Vancouver

Al-Hamash S, Khalid KA, Khalaf OZ. Reliability of Transthoracic Echocardiography to Guide Transcatheter Closure of Atrial Septal Defects. Pathology and Laboratory Medicine. 2021;5(2):38-42. doi:10.11648/j.plm.20210502.14

BibTeX
@article{AlHamash2021,
  author = {Al-Hamash, Sadiq and Khalid, Khalid Ahmed and Khalaf, Omar Zidane},
  title = {Reliability of Transthoracic Echocardiography to Guide Transcatheter Closure of Atrial Septal Defects},
  journal = {Pathology and Laboratory Medicine},
  year = {2021},
  volume = {5},
  number = {2},
  pages = {38--42},
  doi = {10.11648/j.plm.20210502.14}
}
Kostenlos starten →