Point of Care Blood Gas Analyser Verification at the Largest Academic Hospital in Southern Hemisphere Revived by Coronavirus Calls for Tests to Be Verified

Ernest Philani Buthelezi, Edwin Rampota, Matumi Mphogo, Florence Marule, Donald Moshen Tanyanyiwa

Pathology and Laboratory Medicine · 15.06.2020 · 4 (2) · 27-36

DOI: 10.11648/j.plm.20200402.11 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pathology and Laboratory Medicine, online erschienen am 15.06.2020. Verfasst von Ernest Philani Buthelezi und 4 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 17 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

At no point in the history of medicine has the importance of point-of-care testing (POCT) devices, tests and methods verification and utilisation been recognised and accepted than during the coronavirus pandemic. Blood gas analysers offer the best form of POCT and this has been demonstrated in the management of coronavirus patients admitted to hospital intensive care units with respiratory challenges. The new analysers were evaluated in compliance with the Clinical Laboratory Improvement Amendments (CLIA) regulation. The new method must be evaluated by comparison to the central laboratory or the outgoing analyser. The study was undertaken to verify if the new instrument, OMNI S b221 matches the well-established analysers currently in use at the hospital.

Objectives

To evaluate method performance of pH, the partial pressure of carbon dioxide (pCO 2 ), the partial pressure of oxygen (pO 2 ), glucose, lactate, and electrolytes on OMNI S b221 blood gas analyser. Materials and Methods: To analyse the method performance of the pH, pO 2 , pCO 2 , glucose, lactate and electrolytes (Na + , K + Ca ++ ) on OMNI S b221 blood gas analyser 40 samples run on OMNI S b221 blood gas analyser were compared with the results obtained from ABL700, GEM PREMIER for all the parameters and the Roche Hitachi 917 analyser to compare two electrolytes (Na + and K + ). The correlation coefficient was calculated for the results obtained from each paired set of instruments (ABL 700 vs GEM PREMIER and ABL 700 vs OMNI S b221). Comparability between analyser methods performance was determined using linear regression analysis.

Results

The correlation coefficient between the paired analytical platforms were all between 0.81 and 0.99, demonstrating a strong linear relationship. The coefficient of variation for all the parameters were less than 2 also demonstrating good precision.

Conclusion

OMNI S b221 blood gas analyser correlated well with the outgoing ABL 700, GEM PREMIER blood gas analyser and the central laboratory analyser, Roche Hitachi 917 and therefore, verified as a good platform to run arterial blood gas samples.

Zitieren

APA

Buthelezi, E. P., Rampota, E., Mphogo, M., Marule, F., & Tanyanyiwa, D. M. (2020). Point of Care Blood Gas Analyser Verification at the Largest Academic Hospital in Southern Hemisphere Revived by Coronavirus Calls for Tests to Be Verified. Pathology and Laboratory Medicine, 4(2), 27-36. https://doi.org/10.11648/j.plm.20200402.11

Vancouver

Buthelezi EP, Rampota E, Mphogo M, Marule F, Tanyanyiwa DM. Point of Care Blood Gas Analyser Verification at the Largest Academic Hospital in Southern Hemisphere Revived by Coronavirus Calls for Tests to Be Verified. Pathology and Laboratory Medicine. 2020;4(2):27-36. doi:10.11648/j.plm.20200402.11

BibTeX
@article{Buthelezi2020,
  author = {Buthelezi, Ernest Philani and Rampota, Edwin and Mphogo, Matumi and Marule, Florence and Tanyanyiwa, Donald Moshen},
  title = {Point of Care Blood Gas Analyser Verification at the Largest Academic Hospital in Southern Hemisphere Revived by Coronavirus Calls for Tests to Be Verified},
  journal = {Pathology and Laboratory Medicine},
  year = {2020},
  volume = {4},
  number = {2},
  pages = {27--36},
  doi = {10.11648/j.plm.20200402.11}
}
Kostenlos starten →