EUVIMEDEUVIMED entdecken
Crossref

Evaluation of Low Tidal Volume During General Anesthesia in Prone Position on Respiratory Functions

Mohamed Shahat Badawy, Marwa Nasr Eldin Hamed, Ahmed El-Saied Abdel Rahman, Salman Osama Hamdy, Ahmed Yosef Abdel Zaher

International Journal of Anesthesia and Clinical Medicine · 01.07.2018 · 6 (1) · 26-32

DOI: 10.11648/j.ja.20180601.15 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Anesthesia and Clinical Medicine, online erschienen am 01.07.2018. Verfasst von Mohamed Shahat Badawy und 4 weiteren Autor:innen. Die Arbeit nennt 32 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background: Surgery is accompanied by postoperative pulmonary functions impairment especially in the prone position. There is evidence suggested that using low tidal volume during general anesthesia may decrease post-operative lung injury. This study aimed to evaluate the effect of low tidal volume on lung functions during mechanical ventilation for general anesthesia while patients lying in the prone position. A prospective clinical trial was performed on 88 patients ASA I&II scheduled for elective surgery while patients lying prone and were randomly assigned to either protective ventilation group A with tidal volume; 5-7 ml/kg, 10 cm H 2 O positive end expiratory pressure (PEEP) with recruitment maneuver (RM) or conventional group B with Tidal Volume; 10-12 ml/kg, without both PEEP and RM. The primary efficacy variables were assessed by pulmonary function tests, performed before surgery, and 6, 12 and 24 hours postoperatively. Improvement of lung functions were found in the first post-operative 6 and 12 hours in the low tidal volume group and significant difference was found in all parameters P value 0.001 except PaO 2 /FIO 2 ratio P value 0.4. After 24 hours there were significant difference in the FVC, predicted FEV1 and FVC and FEV1/FVC ratio being higher in the low tidal volume group with P value 0.001. Patients in both groups showed similar rates of postoperative chest complications without significant difference. Lung protective ventilation improved lung functions in the first post-operative 24 hours. There was no significant postoperative chest complications difference between the two groups.

Zitieren

APA

Badawy, M. S., Hamed, M. N. E., Rahman, A. E. A., Hamdy, S. O., & Zaher, A. Y. A. (2018). Evaluation of Low Tidal Volume During General Anesthesia in Prone Position on Respiratory Functions. International Journal of Anesthesia and Clinical Medicine, 6(1), 26-32. https://doi.org/10.11648/j.ja.20180601.15

Vancouver

Badawy MS, Hamed MNE, Rahman AEA, Hamdy SO, Zaher AYA. Evaluation of Low Tidal Volume During General Anesthesia in Prone Position on Respiratory Functions. International Journal of Anesthesia and Clinical Medicine. 2018;6(1):26-32. doi:10.11648/j.ja.20180601.15

BibTeX
@article{Badawy2018,
  author = {Badawy, Mohamed Shahat and Hamed, Marwa Nasr Eldin and Rahman, Ahmed El-Saied Abdel and Hamdy, Salman Osama and Zaher, Ahmed Yosef Abdel},
  title = {Evaluation of Low Tidal Volume During General Anesthesia in Prone Position on Respiratory Functions},
  journal = {International Journal of Anesthesia and Clinical Medicine},
  year = {2018},
  volume = {6},
  number = {1},
  pages = {26--32},
  doi = {10.11648/j.ja.20180601.15}
}
Kostenlos starten →