EUVIMEDEUVIMED entdecken
Crossref

A Unified Low-Cost Embedded IoT Framework for Concurrent Physiological and Ambient Air-Quality Monitoring in Patient-Centred Care

Md. Sayem, Md. Hasan, Bishal Paul, Md. Rahman, Dhrubo Roy, Protik Sheikh, Sadman Alam

Internet of Things and Cloud Computing · 10.08.2026 · 14 (2) · 26-37

DOI: 10.11648/j.iotcc.20261402.11 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Internet of Things and Cloud Computing, online erschienen am 10.08.2026. Verfasst von Md. Sayem und 6 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Continuous tracking of a patient's vital signs is now routine, but the air the patient actually breathes is seldom measured by the same inexpensive device, even though air quality is a modifiable factor that affects cardiorespiratory health. Because embedded health monitors and air-quality monitors are usually built as separate products, a caregiver must install, power, and reconcile two devices, and the vital-sign readings arrive without any picture of the environment that produced them. To close this gap, we describe a single low-cost embedded platform that combines a physiological subsystem (a pulse sensor and an LM35 temperature sensor) with an environmental subsystem based on an MQ-135 gas sensor. Both share one Arduino Uno (ATmega328P) edge node, and an ESP32 Wi-Fi gateway relays the readings to the ThingSpeak cloud. A 10-bit ADC digitises every channel; the firmware converts the counts into clinical and air-quality indices, checks them against calibrated thresholds, and reports the outcome through a 16×2 I 2 C LCD, a graduated LED and PWM-buzzer alert stage, and a USART log. Each subsystem was built in hardware and checked against a Proteus simulation. In testing, the physiological subsystem separated normal, tachycardic, and febrile states cleanly (pulse 72-120 bpm; temperature 98.2-101.2°F), and the environmental subsystem classified all four severity levels correctly across five controlled gas trials, with an 8-12 s response time and full simulation-hardware agreement. The assembled prototype costs roughly BDT 1,347 (≈ USD 12.3). Three contributions follow: a single-node architecture serving both domains, a shared threshold-classification and multi-modal alerting scheme that works across them, and a cost model grounded in the actual build. Placing patient vitals and ambient air quality on one affordable node lets the device raise context-aware alerts—such as calling for ventilation when pollutant levels climb near a vulnerable patient—which makes it a practical fit for homes, clinics, and resource-limited settings.

Zitieren

APA

Sayem, M., Hasan, M., Paul, B., Rahman, M., Roy, D., Sheikh, P., & Alam, S. (2026). A Unified Low-Cost Embedded IoT Framework for Concurrent Physiological and Ambient Air-Quality Monitoring in Patient-Centred Care. Internet of Things and Cloud Computing, 14(2), 26-37. https://doi.org/10.11648/j.iotcc.20261402.11

Vancouver

Sayem M, Hasan M, Paul B, Rahman M, Roy D, Sheikh P, et al. A Unified Low-Cost Embedded IoT Framework for Concurrent Physiological and Ambient Air-Quality Monitoring in Patient-Centred Care. Internet of Things and Cloud Computing. 2026;14(2):26-37. doi:10.11648/j.iotcc.20261402.11

BibTeX
@article{Sayem2026,
  author = {Sayem, Md. and Hasan, Md. and Paul, Bishal and Rahman, Md. and Roy, Dhrubo and Sheikh, Protik and Alam, Sadman},
  title = {A Unified Low-Cost Embedded IoT Framework for Concurrent Physiological and Ambient Air-Quality Monitoring in Patient-Centred Care},
  journal = {Internet of Things and Cloud Computing},
  year = {2026},
  volume = {14},
  number = {2},
  pages = {26--37},
  doi = {10.11648/j.iotcc.20261402.11}
}
Kostenlos starten →