EUVIMEDEUVIMED entdecken
Crossref

Evaluation of the Effect of Bone Grafts in Different Sizes and Forms Used During Alveolar Split Osteotomy on the Implant Stability

Ugur Mercan, Suheyla Kaya

International Journal of Clinical Oral and Maxillofacial Surgery · 13.07.2020 · 6 (2) · 34-39

DOI: 10.11648/j.ijcoms.20200602.13 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Clinical Oral and Maxillofacial Surgery, online erschienen am 13.07.2020. Verfasst von Ugur Mercan und 1 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To compare the effects of filling bone gap between implants with bone graft materials of different sizes and forms of primary stability after alveolar split osteotomy process. Materials and Methods: Materials and Methods: Fourty fresh ribs were divided into four main groups. The groups created are based on the xenograft material of different sizes and forms; group Putty (P): Group applied Putty (form) graft (granule size 0.25– 1 mm), group Small (S): Group applied Small particle graft (granule size 0.25– 1 mm) group, group Large (L): Group applied Large particle graft (granule size 1– 2 mm), control group (C): classified as group where no bone graft was applied. Bone expansion was performed using piezosurgery. In all groups, two implants were inserted into the each rib after alveolar crest expansions. The gap between implants (outside the control group) was filled with bone graft materials of different forms and sizes (large, small, putty). The primary stability values of the implants were measured with in the direction of the bucco-lingual (BL) and mesio-distal (MD) by the ISQ (implant stability quotient) and compared between groups.

Results

The primary stability values measured in the BL direction are higher than the primary stability values measured in the MD direction and values are statistically significant difference. There is no statistically significant difference between the 1st and 2nd implants in each group (C, P, S, L) for their measured values in both BL direction and MD direction.

Conclusion

According to the ISQ values used to evaluate primary stability, it was found that the graft materials of different sizes used in our study did not cause a significant difference for the primary stability of the implants.

Zitieren

APA

Mercan, U., & Kaya, S. (2020). Evaluation of the Effect of Bone Grafts in Different Sizes and Forms Used During Alveolar Split Osteotomy on the Implant Stability. International Journal of Clinical Oral and Maxillofacial Surgery, 6(2), 34-39. https://doi.org/10.11648/j.ijcoms.20200602.13

Vancouver

Mercan U, Kaya S. Evaluation of the Effect of Bone Grafts in Different Sizes and Forms Used During Alveolar Split Osteotomy on the Implant Stability. International Journal of Clinical Oral and Maxillofacial Surgery. 2020;6(2):34-39. doi:10.11648/j.ijcoms.20200602.13

BibTeX
@article{Mercan2020,
  author = {Mercan, Ugur and Kaya, Suheyla},
  title = {Evaluation of the Effect of Bone Grafts in Different Sizes and Forms Used During Alveolar Split Osteotomy on the Implant Stability},
  journal = {International Journal of Clinical Oral and Maxillofacial Surgery},
  year = {2020},
  volume = {6},
  number = {2},
  pages = {34--39},
  doi = {10.11648/j.ijcoms.20200602.13}
}
Kostenlos starten →