EUVIMEDEUVIMED entdecken
Crossref

Analysis of Electrical Resistivity Survey Data for Aquifer Potential and Protective Capacity at Mararaba Dan-Daudu Minna, North Central Nigeria

Alfa Idris Alhaji, Salako Kazeem Adeyinka, Rafiu Abdulwaheed Adewuyi, Udensi Emmanuel Emeka, Adetona Abbas Adebayo, Jamilu Shehu

Hydrology · 28.10.2023 · 11 (4) · 67-84

DOI: 10.11648/j.hyd.20231104.12 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Hydrology, online erschienen am 28.10.2023. Verfasst von Alfa Idris Alhaji und 5 weiteren Autor:innen. Die Arbeit nennt 45 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

It is a fact that basement complex regions lacks sufficient overburden that can host sustainable water table, water bearing fractured/weathered rocks referred to as aquifers are usually identified via suitable geophysical methods to proffer solution to water challenges within these regions. This current study targets the exploration of groundwater potential within the Mararaba Dan-daudu community, a suburb of Minna metropolis. Electrical resistivity method was employed to delineate aquifer prospects and their protective capacity within the area of study. The data from thirty-six Vertical Electrical Sounding (VES) survey points were acquired and analysed. Survey points were aligned along six profiles (A – F) with six VES points per profile. Interpretation of VES points along profiles was helpful in determining the number of layers and thickness. The analysis revealed mainly three layers comprising of sand and fresh laterite at the first layer, fractured/weathered basement at the second layer and fresh basement at the third layer. Iso-resistivity mapping was also done at various depths (surface, 5 m, 10 m, 15 m, 20 m, 30 m and 40 m) respectively to investigate the lateral variations of resistivity over a horizontal plane. These showcased the electrical conductance sliced at the depths of interest. Thirteen VES points (A1, A5, A6, B1, B3, B6, C6, D6, E6, F1, F2, F4 and F5) were mapped as having good prospective aquifer properties. Longitudinal conductance was computed for the outlined VES points to determine their Aquifer Protective Capacity (APC). The result of (APC) rating for the 13 VES revealed the frequency and percentage of APC ranged as: 2 VES locations (15.4%) have good APC, 8 VES locations (61.5%) have moderate APC and 3 VES location (23.1%) have weak APC. with only 3 VES locations out of 13 VES locations in the study area revealed weak APC, the results proved that the groundwater potential of the study area has moderately good APC.

Zitieren

APA

Alhaji, A. I., Adeyinka, S. K., Adewuyi, R. A., Emeka, U. E., Adebayo, A. A., & Shehu, J. (2023). Analysis of Electrical Resistivity Survey Data for Aquifer Potential and Protective Capacity at Mararaba Dan-Daudu Minna, North Central Nigeria. Hydrology, 11(4), 67-84. https://doi.org/10.11648/j.hyd.20231104.12

Vancouver

Alhaji AI, Adeyinka SK, Adewuyi RA, Emeka UE, Adebayo AA, Shehu J. Analysis of Electrical Resistivity Survey Data for Aquifer Potential and Protective Capacity at Mararaba Dan-Daudu Minna, North Central Nigeria. Hydrology. 2023;11(4):67-84. doi:10.11648/j.hyd.20231104.12

BibTeX
@article{Alhaji2023,
  author = {Alhaji, Alfa Idris and Adeyinka, Salako Kazeem and Adewuyi, Rafiu Abdulwaheed and Emeka, Udensi Emmanuel and Adebayo, Adetona Abbas and Shehu, Jamilu},
  title = {Analysis of Electrical Resistivity Survey Data for Aquifer Potential and Protective Capacity at Mararaba Dan-Daudu Minna, North Central Nigeria},
  journal = {Hydrology},
  year = {2023},
  volume = {11},
  number = {4},
  pages = {67--84},
  doi = {10.11648/j.hyd.20231104.12}
}
Kostenlos starten →