Diagnostic Load Test of a Scaled Post-Tensioned Flat Plate Concrete Slab
Engineering and Applied Sciences · 11.09.2025 · 10 (5) · 114-122
DOI: 10.11648/j.eas.20251005.11 ↗Kurz gefasst
Fachartikel in der Zeitschrift Engineering and Applied Sciences, online erschienen am 11.09.2025. Verfasst von Mohammed Faruqi und 1 weiteren Autor:innen. Die Arbeit nennt 15 Literaturangaben.
Abstract (Originalsprache)
A flat plate floor system is a concrete system that has uniform thickness. They are generally cast-in-place or they may be casted at the ground level and lifted into their final position by the use of jacks at the columns. This system can be post-tensioned. Flat plate post tensioned concrete slabs are widely used in office buildings, institutional structures, parking structures, apartment buildings, and hotels. Therefore, it is important to have a good understanding of the behavior of these elements that form the fabric of the total structural system. The main goal of this work was to perform a design evaluation on a constructed scaled post-tensioned 4 ft x 4 ft flat plate concrete slab with American Concrete Institute (ACI) design provisions. The 28 days compressive strength of concrete was 5000 psi. The slab thickness was 1/2 in, and 1/16 in post-tensioning cables inside a plastic sheathing were used as the reinforcement. The slab was loaded using a designed water tank of 4 ft x 4 ft x 6 ft dimensions. The water depth generated the distributed load on the slab and a dial gauge measured the slab deflections. Distributed load and deflection data were collected. The design evaluations were carried out with respect to deflections, stresses, shear and flexural capacity using a developed ACI provisioned spreadsheet and experimentally obtained load and deflection data. The scaled constructed concrete slab satisfied the ACI design provisions.
Zitieren
APA
Faruqi, M., & Vargas, C. (2025). Diagnostic Load Test of a Scaled Post-Tensioned Flat Plate Concrete Slab. Engineering and Applied Sciences, 10(5), 114-122. https://doi.org/10.11648/j.eas.20251005.11
Vancouver
Faruqi M, Vargas C. Diagnostic Load Test of a Scaled Post-Tensioned Flat Plate Concrete Slab. Engineering and Applied Sciences. 2025;10(5):114-122. doi:10.11648/j.eas.20251005.11
BibTeX
@article{Faruqi2025,
author = {Faruqi, Mohammed and Vargas, Carlos},
title = {Diagnostic Load Test of a Scaled Post-Tensioned Flat Plate Concrete Slab},
journal = {Engineering and Applied Sciences},
year = {2025},
volume = {10},
number = {5},
pages = {114--122},
doi = {10.11648/j.eas.20251005.11}
}
EUVIMED