Behavior of Fiber Reinforced Polymer (FRP) Confined Crumb Rubber Concrete at Elevated Temperatures

Mohammed Faruqi, Ajibola Habeeb Alamutu, Breanna Bailey, Francisco Aguiniga

Engineering and Applied Sciences · 09.06.2023 · 8 (3) · 36-46

DOI: 10.11648/j.eas.20230803.11 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Engineering and Applied Sciences, online erschienen am 09.06.2023. Verfasst von Mohammed Faruqi und 3 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Researchers in engineering and sciences have consistently carried out relevant studies on different ways to minimize the use of natural resources and to control environmental pollution. Aggregates used in concrete are generally obtained from rocks while huge collection of scrap tires are one of the biggest form of wastes in our societies throughout the world. Studies have shown that aggregates in conventional concrete (CC) can be partially replaced with crumb rubber particles. This type of concrete can be referred to as Crumb Rubber Concrete (CRC). Confinement of crumb rubber concrete and conventional concrete have shown to increase their compressive strengths. However, the behavior of CRC confined with Carbon Fiber Reinforced Polymer (CFRP) sheets at elevated temperatures is still unknown. The knowledge and application of this could lead to a cost-effective and practical consideration in fire safety design. Therefore, this study examines the confined compressive strength of CRC confined with CFRP sheets at elevated temperatures. Finite Element Models (FEM) of CC and CRC with and without confinement were developed at room temperature and validated with literature, American Concrete Institute (ACI), and an indirect reference to the real behavior of the material. FEM results agreed reasonably with these sources. Finite element models of confined CC and confined CRC were subjected to elevated temperature and compared with the finite element model of confined CC and confined CRC respectively at room temperature. It was found that models under service confined compressive stress subjected to elevated temperature of 120°C experienced strength loss in the range of 46% to 51% when compared with the room temperature. Accordingly, a strength loss in the range of 34% to 56% was observed for models under maximum confined compressive stress. An example of an axially loaded CFRP-confined CRC column with explanations to calculate the nominal load capacity of a modeled column at room temperature and elevated temperature using our data was also carried out. The percentage difference between the calculated and the model were respectively 3% and 12.1% at room and elevated temperature.

Zitieren

APA

Faruqi, M., Alamutu, A. H., Bailey, B., & Aguiniga, F. (2023). Behavior of Fiber Reinforced Polymer (FRP) Confined Crumb Rubber Concrete at Elevated Temperatures. Engineering and Applied Sciences, 8(3), 36-46. https://doi.org/10.11648/j.eas.20230803.11

Vancouver

Faruqi M, Alamutu AH, Bailey B, Aguiniga F. Behavior of Fiber Reinforced Polymer (FRP) Confined Crumb Rubber Concrete at Elevated Temperatures. Engineering and Applied Sciences. 2023;8(3):36-46. doi:10.11648/j.eas.20230803.11

BibTeX
@article{Faruqi2023,
  author = {Faruqi, Mohammed and Alamutu, Ajibola Habeeb and Bailey, Breanna and Aguiniga, Francisco},
  title = {Behavior of Fiber Reinforced Polymer (FRP) Confined Crumb Rubber Concrete at Elevated Temperatures},
  journal = {Engineering and Applied Sciences},
  year = {2023},
  volume = {8},
  number = {3},
  pages = {36--46},
  doi = {10.11648/j.eas.20230803.11}
}
Kostenlos starten →