EUVIMEDEUVIMED entdecken
Crossref

Voltammetric Assessment of Paracetamol on a CuONPs – MWCNTs Modified Glassy Carbon Electrode

Rajesh Hegde, Vishwanatha Poojary, Kiran Kamath

American Journal of Physical Chemistry · 15.08.2024 · 13 (3) · 59-65

DOI: 10.11648/j.ajpc.20241303.11 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Physical Chemistry, online erschienen am 15.08.2024. Verfasst von Rajesh Hegde und 2 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this work, an electrochemical sensor using differential pulse voltammetric method for the assessment of antipyretic and analgesic drug, paracetamol was developed. The CuO nanoparticles were synthesized and characterized. A glassy carbon electrode (GCE) fabricated with the suspension of CuO nanoparticles (CuONPs) and multi-walled carbon nanotubes (MWCNTs) were used. The fabricated electrode was characterized using Potassium ferricyanide as a redox probe, which showed increase in the electro active area in the modified electrode. The modified electrode showed improved anodic peak current enhancement in phosphate buffer solution. The consequence of pH of supporting electrolyte and amount of nanoparticles suspension were investigated at a physiological pH of 7.4. Using differential pulse voltammetry, the fabricated electrode showed linear dynamic range from 9 to 160 nM of paracetamol concentration. From the calibration plot, the computed detection limit was 5.06nM and quantification limit was16.88 nM. The developed method was checked for its reproducibility and assay during a day and intraday as well and the results were good with permitted range of errors. The developed process was fruitfully applied to detect paracetamol in pharmaceutical formulations.

Zitieren

APA

Hegde, R., Poojary, V., & Kamath, K. (2024). Voltammetric Assessment of Paracetamol on a CuONPs – MWCNTs Modified Glassy Carbon Electrode. American Journal of Physical Chemistry, 13(3), 59-65. https://doi.org/10.11648/j.ajpc.20241303.11

Vancouver

Hegde R, Poojary V, Kamath K. Voltammetric Assessment of Paracetamol on a CuONPs – MWCNTs Modified Glassy Carbon Electrode. American Journal of Physical Chemistry. 2024;13(3):59-65. doi:10.11648/j.ajpc.20241303.11

BibTeX
@article{Hegde2024,
  author = {Hegde, Rajesh and Poojary, Vishwanatha and Kamath, Kiran},
  title = {Voltammetric Assessment of Paracetamol on a CuONPs – MWCNTs Modified Glassy Carbon Electrode},
  journal = {American Journal of Physical Chemistry},
  year = {2024},
  volume = {13},
  number = {3},
  pages = {59--65},
  doi = {10.11648/j.ajpc.20241303.11}
}
Kostenlos starten →