EUVIMEDEUVIMED entdecken
Vergleichsstudie

Analysis of heart rate variability of an anencephalic fetus using a new method to determine a fractal dimension of non-stationary time-serial data

H Shono, M Shono, T Iwasaka, H Sugimori

Frontiers of Medical and Biological Engineering · 2000

DOI: 10.1163/156855700750265495 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Frontiers of Medical and Biological Engineering, 2000. Verfasst von H Shono und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Obstetrics and Gynecology, Saga Medical School, Japan. shonoh@post.saga-med.ac.jp. Die Arbeit wurde bisher 1-mal zitiert (Crossref).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Human fetal heart rate (HR) variabilities were analyzed using the QIS-A, which we devised to determine a fractal dimension of non-stationary time series. Fifteen 10-min HR data of an anencephalic fetus at 23 weeks and 3 days of gestation and those of 10 normal fetuses at the same weeks of gestation were obtained by ultrasonic cardiography. The anencephalus preserved the spinal cord, medulla and partial anterior hypothalamus. The fractal scaling exponent alpha of the anencephalus was compared with that of each normal fetus by Student's t-test. In results, the scaling relationship in each case had a crossover pattern characterized by alpha(s) and alpha(l), which were slopes above and below a crossover point, respectively. Differences in mean alpha(s) and mean alpha(l) between the anencephalus and each normal fetus were significant (P < 0.01): mean alpha(s), 1.0 +/- 0.1 (+/-SD) (1/f fluctuation) and 1.6 +/- 0.2 (+/-SEM); mean alpha(l), 1.6 +/- 0.2 (+/-SD) and 1.4 +/- 0.1 (+/-SEM). There were six significant differences in mean crossover point between the anencephalus and each normal fetus: 13.8 +/- 5.7 s (+/-SD) and 15.3 +/- 5.6 s (+/-SEM). These results reveal the relationship between fractal structure of fetal HR variability and the developing central nervous system (CNS). In particular, the 1/f fluctuation of HR variability in an anencephalic fetus from the 1.25 to 13.8 s time scale might have a strong relation to the defect of the CNS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AlgorithmsAnencephalyEchocardiography, DopplerFemaleFractalsGestational AgeHeart Rate, FetalHumansPregnancyReference ValuesUltrasonography, Prenatal

Autor:innen und Institutionen

  • Department of Obstetrics and Gynecology, Saga Medical School, Japan. shonoh@post.saga-med.ac.jp

Zitieren

APA

Shono, H., Shono, M., Iwasaka, T., & Sugimori, H. (2000). Analysis of heart rate variability of an anencephalic fetus using a new method to determine a fractal dimension of non-stationary time-serial data. Frontiers of Medical and Biological Engineering. https://doi.org/10.1163/156855700750265495

Vancouver

Shono H, Shono M, Iwasaka T, Sugimori H. Analysis of heart rate variability of an anencephalic fetus using a new method to determine a fractal dimension of non-stationary time-serial data. Frontiers of Medical and Biological Engineering. 2000. doi:10.1163/156855700750265495

BibTeX
@article{Shono2000,
  author = {Shono, H and Shono, M and Iwasaka, T and Sugimori, H},
  title = {Analysis of heart rate variability of an anencephalic fetus using a new method to determine a fractal dimension of non-stationary time-serial data},
  journal = {Frontiers of Medical and Biological Engineering},
  year = {2000},
  doi = {10.1163/156855700750265495}
}
Kostenlos starten →