EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Multimodal Fitting Approach to Construct Single-Neuron Models With Patch Clamp and High-Density Microelectrode Arrays

Alessio Paolo Buccino, Tanguy Damart, Julian Bartram, Darshan Mandge, Xiaohan Xue, Mickael Zbili, Tobias Gänswein, Aurélien Jaquier, Vishalini Emmenegger, Henry Markram, Andreas Hierlemann, Werner Van Geit

Neural Computation · 2024

DOI: 10.1162/neco_a_01672 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Neural Computation, 2024. Verfasst von Alessio Paolo Buccino und 11 weiteren Autor:innen. Beteiligte Einrichtung: Bio Engineering Laboratory, Department of Biosystems Science and Engineering, ETH Zurich, 4056 Basel, Switzerland alessiop.buccino@gmail.com. Hauptthemen laut MEDLINE: Microelectrodes, Neurons, Patch-Clamp Techniques, Models, Neurological. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 76 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: ETH Zurich Postdoctoral Fellowship, Blue Brain Project, European Union’s Horizon 2020 Framework Programme for Research and Innovation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In computational neuroscience, multicompartment models are among the most biophysically realistic representations of single neurons. Constructing such models usually involves the use of the patch-clamp technique to record somatic voltage signals under different experimental conditions. The experimental data are then used to fit the many parameters of the model. While patching of the soma is currently the gold-standard approach to build multicompartment models, several studies have also evidenced a richness of dynamics in dendritic and axonal sections. Recording from the soma alone makes it hard to observe and correctly parameterize the activity of nonsomatic compartments. In order to provide a richer set of data as input to multicompartment models, we here investigate the combination of somatic patch-clamp recordings with recordings of high-density microelectrode arrays (HD-MEAs). HD-MEAs enable the observation of extracellular potentials and neural activity of neuronal compartments at subcellular resolution. In this work, we introduce a novel framework to combine patch-clamp and HD-MEA data to construct multicompartment models. We first validate our method on a ground-truth model with known parameters and show that the use of features extracted from extracellular signals, in addition to intracellular ones, yields models enabling better fits than using intracellular features alone. We also demonstrate our procedure using experimental data by constructing cell models from in vitro cell cultures. The proposed multimodal fitting procedure has the potential to augment the modeling efforts of the computational neuroscience community and provide the field with neuronal models that are more realistic and can be better validated.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MicroelectrodesNeuronsPatch-Clamp TechniquesModels, NeurologicalAnimalsAction PotentialsComputer Simulation

Autor:innen und Institutionen

  • Bio Engineering Laboratory, Department of Biosystems Science and Engineering, ETH Zurich, 4056 Basel, Switzerland alessiop.buccino@gmail.com.
  • Blue Brain Project, École polytechnique fédérale de Lausanne, Campus Biotech, 1202 Geneva, Switzerland tanguy.damart@ksvi.mff.cuni.cz.
  • Bio Engineering Laboratory, Department of Biosystems Science and Engineering, ETH Zurich, 4056 Basel, Switzerland julian.bartram@bsse.ethz.ch.
  • Blue Brain Project, École polytechnique fédérale de Lausanne, Campus Biotech, 1202 Geneva, Switzerland darshan.mandge@epfl.ch.
  • Bio Engineering Laboratory, Department of Biosystems Science and Engineering, ETH Zurich, 4056 Basel, Switzerland xiaohan.xue@bsse.ethz.ch.
  • Blue Brain Project, École polytechnique fédérale de Lausanne, Campus Biotech, 1202 Geneva, Switzerland zbili.mickael@gmail.com.

Förderung

  • ETH Zurich Postdoctoral Fellowship
  • Blue Brain Project
  • European Union’s Horizon 2020 Framework Programme for Research and Innovation

Zitieren

APA

Buccino, A. P., Damart, T., Bartram, J., Mandge, D., Xue, X., Zbili, M., Gänswein, T., Jaquier, A., Emmenegger, V., Markram, H., Hierlemann, A., & Van Geit, W. (2024). A Multimodal Fitting Approach to Construct Single-Neuron Models With Patch Clamp and High-Density Microelectrode Arrays. Neural Computation. https://doi.org/10.1162/neco_a_01672

Vancouver

Buccino AP, Damart T, Bartram J, Mandge D, Xue X, Zbili M, et al. A Multimodal Fitting Approach to Construct Single-Neuron Models With Patch Clamp and High-Density Microelectrode Arrays. Neural Computation. 2024. doi:10.1162/neco_a_01672

BibTeX
@article{Buccino2024,
  author = {Buccino, Alessio Paolo and Damart, Tanguy and Bartram, Julian and Mandge, Darshan and Xue, Xiaohan and Zbili, Mickael and Gänswein, Tobias and Jaquier, Aurélien and Emmenegger, Vishalini and Markram, Henry and Hierlemann, Andreas and Van Geit, Werner},
  title = {A Multimodal Fitting Approach to Construct Single-Neuron Models With Patch Clamp and High-Density Microelectrode Arrays},
  journal = {Neural Computation},
  year = {2024},
  doi = {10.1162/neco_a_01672}
}
Kostenlos starten →