Formal Verification of Deep Brain Stimulation Controllers for Parkinson's Disease Treatment
Neural Computation · 2023
DOI: 10.1162/neco_a_01569 ↗Kurz gefasst
Fachartikel in der Zeitschrift Neural Computation, 2023. Verfasst von Arooj Nawaz und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Electrical Engineering and Computer Science, National University of Sciences and Technology, Islamabad 44000, Pakistan arooj.nawaz@seecs.ed…. Hauptthemen laut MEDLINE: Parkinson Disease, Deep Brain Stimulation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben.
Abstract (Originalsprache)
Deep brain stimulation (DBS) is a widely accepted treatment for the Parkinson's disease (PD). Traditionally, it is done in an open-loop manner, where stimulation is always ON, irrespective of the patient needs. As a consequence, patients can feel some side effects due to the continuous high-frequency stimulation. Closed-loop DBS can address this problem as it allows adjusting stimulation according to the patient need. The selection of open- or closed-loop DBS and an optimal algorithm for closed-loop DBS are some of the main challenges in DBS controller design, and typically the decision is made through sampling based simulations. In this letter, we used model checking, a formal verification technique used to exhaustively explore the complete state space of a system, for analyzing DBS controllers. We analyze the timed automata of the open-loop and closed-loop DBS controllers in response to the basal ganglia (BG) model. Furthermore, we present a formal verification approach for the closed-loop DBS controllers using timed computation tree logic (TCTL) properties, that is, safety, liveness (the property that under certain conditions, some event will eventually occur), and deadlock freeness. We show that the closed-loop DBS significantly outperforms existing open-loop DBS controllers in terms of energy efficiency. Moreover, we formally analyze the closed-loop DBS for energy efficiency and time behavior with two algorithms, the constant update algorithm and the error prediction update algorithm. Our results demonstrate that the closed-loop DBS running the error prediction update algorithm is efficient in terms of time and energy as compared to the constant update algorithm.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- School of Electrical Engineering and Computer Science, National University of Sciences and Technology, Islamabad 44000, Pakistan arooj.nawaz@seecs.edu.pk.
- School of Electrical Engineering and Computer Science, National University of Sciences and Technology, Islamabad 44000, Pakistan osman.hasan@seecs.edu.pk.
- Electrical and Computer Engineering Department, COMSATS University, Islamabad 45550, Pakistan shaista.sj@comsats.edu.pk.
Zitieren
APA
Nawaz, A., Hasan, O., & Jabeen, S. (2023). Formal Verification of Deep Brain Stimulation Controllers for Parkinson's Disease Treatment. Neural Computation. https://doi.org/10.1162/neco_a_01569
Vancouver
Nawaz A, Hasan O, Jabeen S. Formal Verification of Deep Brain Stimulation Controllers for Parkinson's Disease Treatment. Neural Computation. 2023. doi:10.1162/neco_a_01569
BibTeX
@article{Nawaz2023,
author = {Nawaz, Arooj and Hasan, Osman and Jabeen, Shaista},
title = {Formal Verification of Deep Brain Stimulation Controllers for Parkinson's Disease Treatment},
journal = {Neural Computation},
year = {2023},
doi = {10.1162/neco_a_01569}
}
EUVIMED