Determining sensor geometry and gain in a wearable MEG system

Ryan M Hill, Gonzalo Reina Rivero, Ashley J Tyler, Holly Schofield, Cody Doyle, James Osborne, David Bobela, Lukas Rier, Joseph Gibson, Zoe Tanner, Elena Boto, Richard Bowtell und 3 weitere

Imaging Neuroscience · 08.04.2025 · 3

DOI: 10.1162/imag_a_00535 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Imaging Neuroscience, online erschienen am 08.04.2025. Verfasst von Ryan M Hill und 14 weiteren Autor:innen. Beteiligte Einrichtung: Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, United Kingdom. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 70 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NHLBI NIH HHS, NIMH NIH HHS, Innovate UK.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Optically-pumped magnetometers (OPMs) are compact and lightweight sensors that can measure magnetic fields generated by current flow in neuronal assemblies in the brain. Such sensors enable construction of magnetoencephalography (MEG) instrumentation, with significant advantages over conventional MEG devices, including adaptability to head size, enhanced movement tolerance, lower complexity, and improved data quality. However, realising the potential of OPMs depends on our ability to perform system calibration—which means finding sensor locations, orientations, and the relationship between the sensor output and magnetic field (termed sensor gain). Such calibration is complex in OPM-MEG since, for example, OPM placement can change from subject to subject (unlike in conventional MEG where sensor locations/orientations are fixed). Here, we present two methods for calibration, both based on generating well-characterised magnetic fields across a sensor array. Our first device (the HALO) is a head mounted system that generates dipole-like fields from a set of coils. Our second (the matrix coil (MC)) generates fields using coils embedded in the walls of a magnetically shielded room. Our results show that both methods offer an accurate means to calibrate an OPM array (e.g., sensor locations within 2 mm of the ground truth) and that the calibrations produced by the two methods agree strongly with each other: reconstructed positions, orientations, and gains differ on average by 2.0 mm; 1.2° and 1.3% between HALO and MC. When applied to data from human MEG experiments, both methods offer improved signal-to-noise ratio after beamforming, suggesting that they give calibration parameters closer to the ground truth than presumed physical sensor coordinates and orientations. Both techniques are practical and easy to integrate into real-world MEG applications. This advances the field significantly closer to the routine use of OPMs for MEG recording.

Schlagwörter

Stichwörter der Autor:innen

calibrationmagnetoencephalography (MEG)optically-pumped magnetometer

Autor:innen und Institutionen

  • Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, United Kingdom.
  • Cerca Magnetics Limited, Nottingham, United Kingdom.
  • QuSpin Inc., Louisville, CO, United States.

ORCID-Profile: Niall Holmes

Förderung

  • NHLBI NIH HHS
  • NIMH NIH HHS
  • Innovate UK
  • Quantum Technology Hub in Sensing and Timing, funded by EPSRC
  • Engineering and Physical Sciences Research Council (EPSRC) Healthcare Impact Partnership
  • Medical Research Council
  • National Institutes of Health

Zitieren

APA

Hill, R. M., Reina Rivero, G., Tyler, A. J., Schofield, H., Doyle, C., Osborne, J., Bobela, D., Rier, L., Gibson, J., Tanner, Z., Boto, E., Bowtell, R., Brookes, M. J., Shah, V., & Holmes, N. (2025). Determining sensor geometry and gain in a wearable MEG system. Imaging Neuroscience, 3. https://doi.org/10.1162/imag_a_00535

Vancouver

Hill RM, Reina Rivero G, Tyler AJ, Schofield H, Doyle C, Osborne J, et al. Determining sensor geometry and gain in a wearable MEG system. Imaging Neuroscience. 2025;3. doi:10.1162/imag_a_00535

BibTeX
@article{Hill2025,
  author = {Hill, Ryan M and Reina Rivero, Gonzalo and Tyler, Ashley J and Schofield, Holly and Doyle, Cody and Osborne, James and Bobela, David and Rier, Lukas and Gibson, Joseph and Tanner, Zoe and Boto, Elena and Bowtell, Richard and Brookes, Matthew J and Shah, Vishal and Holmes, Niall},
  title = {Determining sensor geometry and gain in a wearable MEG system},
  journal = {Imaging Neuroscience},
  year = {2025},
  volume = {3},
  doi = {10.1162/imag_a_00535}
}
Kostenlos starten →