Validating genuine changes in heartbeat-evoked potentials using pseudotrials and surrogate procedures
Imaging Neuroscience · 10.06.2025 · 3
DOI: 10.1162/imag.a.30 ↗Kurz gefasst
Fachartikel in der Zeitschrift Imaging Neuroscience, online erschienen am 10.06.2025. Verfasst von Paul Steinfath und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurology, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 81 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: LIFE Leipzig Research Center for Civilization Diseases.
Abstract (Originalsprache)
The brain continuously receives interoceptive information about the state and function of our internal organs. For instance, each time the heart beats, the brain responds by generating time-locked activity, known as heartbeat-evoked potentials (HEP). When investigating HEPs, it is essential to adequately control for heartbeat-independent confounding activity to avoid false interpretations. In the present study, we highlight the pitfalls of uncontrolled analyses and advocate for the use of surrogate heartbeat analysis and pseudotrial correction, which are promising tools to control for spurious results. Surrogate heartbeat analysis involves shuffling the timing of heartbeats to verify the time-locking of HEP effects. Pseudotrial correction works by subtracting heartbeat-independent activity from HEPs. In this study, we employ both procedures, validate them in simulations, and apply them to real electroencephalography (EEG) data. Using EEG recordings obtained during the performance of an auditory novelty oddball task in a large population, we show that, without control analyses, pre-stimulus HEPs appear inversely related to task-related measures such as P300 event-related potential amplitudes and reaction time speed. However, these effects disappear after carefully controlling for heartbeat-unrelated EEG activity. Additionally, in real and simulated data, we show that pseudotrial correction has the potential to remove task-related confounds from HEPs, thereby uncovering real heartbeat-related effects that otherwise could be missed. This study, therefore, highlights issues that can arise when analyzing HEPs during tasks, provides solutions to overcome them, and gives recommendations for future studies to avoid pitfalls when analyzing and designing experiments involving HEPs.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Neurology, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany.
- International Max Planck Research School NeuroCom, Leipzig, Germany.
- Max Planck School of Cognition, Leipzig, Germany.
- Department of Psychiatry and Psychotherapy, University of Leipzig Medical Center, Leipzig, Germany.
- LIFE - Leipzig Research Center for Civilization Diseases, University of Leipzig, Leipzig, Germany.
- Department of Cognitive Neurology, University Hospital Leipzig, Leipzig, Germany.
ORCID-Profile: Paul Steinfath, Nadine Herzog, Antonin Fourcade, Christian Sander, Vadim Nikulin, Arno Villringer
Förderung
- LIFE Leipzig Research Center for Civilization Diseases
Zitieren
APA
Steinfath, P., Herzog, N., Fourcade, A., Sander, C., Nikulin, V., & Villringer, A. (2025). Validating genuine changes in heartbeat-evoked potentials using pseudotrials and surrogate procedures. Imaging Neuroscience, 3. https://doi.org/10.1162/imag.a.30
Vancouver
Steinfath P, Herzog N, Fourcade A, Sander C, Nikulin V, Villringer A. Validating genuine changes in heartbeat-evoked potentials using pseudotrials and surrogate procedures. Imaging Neuroscience. 2025;3. doi:10.1162/imag.a.30
BibTeX
@article{Steinfath2025,
author = {Steinfath, Paul and Herzog, Nadine and Fourcade, Antonin and Sander, Christian and Nikulin, Vadim and Villringer, Arno},
title = {Validating genuine changes in heartbeat-evoked potentials using pseudotrials and surrogate procedures},
journal = {Imaging Neuroscience},
year = {2025},
volume = {3},
doi = {10.1162/imag.a.30}
}
EUVIMED