EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Frequency-dependence in multidimensional diffusion–relaxation correlation MRI of the brain: Overfitting or meaningful parameter?

Maxime Yon iD, Omar Narvaez, Jan Martin, Hong Jiang, Diana Bernin, Eva Forssell-Aronsson, Frederik Laun, Alejandra Sierra, Daniel Topgaard

Imaging Neuroscience · 22.09.2025 · 3

DOI: 10.1162/imag.a.143 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Imaging Neuroscience, online erschienen am 22.09.2025. Verfasst von Maxime Yon und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Lund University, Lund, Sweden. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 161 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Swedish Foundation for Strategic Research, Swedish Research Council, Swedish Cancer Society.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Time- or frequency-dependent (“restricted”) diffusion potentially provides useful information about cellular-scale structures in the brain but is challenging to interpret because of intravoxel tissue heterogeneity. Multidimensional diffusion–relaxation correlation MRI with tensor-valued diffusion encoding enables characterization of intravoxel heterogeneity in terms of nonparametric distributions of diffusion tensors and nuclear relaxation rates, and was recently augmented with explicit consideration of frequency-dependence to resolve the effects of restricted diffusion for distinct populations of tissue water. The simplest acquisition protocols for tensor-valued encoding unintentionally cover a frequency range of a factor 2–3, which can be extended in a more controlled way with oscillating gradient waveforms. While microimaging equipment with high-amplitude magnetic field gradients allows exploration of frequencies from tens to hundreds of Hz, clinical scanners with more moderate gradient capabilities are limited to narrower ranges that may be insufficient to observe restricted diffusion for brain tissues. We here investigate the effects of including or omitting frequency-dependence in the data inversion from isotropic and anisotropic liquids, excised tumor tissue, ex vivo mouse brain, and in vivo human brain. For microimaging measurements covering a wide frequency range, from 35 to 320 Hz at b-values over 4·109 sm−2, the inclusion of frequency-dependence drastically reduces fit residuals and avoids bias in the diffusion metrics for tumor and brain voxels with micrometer-scale structures. Conversely, for the case of in vivo human brain investigated in the narrow frequency range from 5 to 11 Hz at b = 3·109 sm−2, analyses with and without inclusion of frequency-dependence yield similar fit residuals and diffusion metrics for all voxels. These results indicate that frequency-dependent inversion may be generally applied to diffusion–relaxation correlation MRI data with and without observable effects of restricted diffusion.

Schlagwörter

Stichwörter der Autor:innen

Monte Carlo data inversiondiffusion MRIfrequency-dependent diffusionmultidimensional MRIoscillating gradient spin echo (OGSE)spectrally modulated gradientstensor-valued diffusion encoding

Autor:innen und Institutionen

  • Department of Chemistry, Lund University, Lund, Sweden.
  • A.I. Virtanen Institute for Molecular Sciences, University of Eastern Finland, Kuopio, Finland.
  • Department of Chemical Engineering, Chalmers University of Technology, Gothenburg, Sweden.
  • Department of Medical Radiation Sciences, University of Gothenburg, Gothenburg, Sweden.
  • Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden.
  • Department of Radiology, University Hospital Erlangen, Friedrich-Alexander Universität Erlangen-Nürnberg, Erlangen, Germany.

ORCID-Profile: Maxime Yon

Förderung

  • Swedish Foundation for Strategic Research
  • Swedish Research Council
  • Swedish Cancer Society
  • Swedish Childhood Cancer Fund, Academy of Finland
  • Erkko Foundation
  • China Scholarship Council

Zitieren

APA

Yon, M., Narvaez, O., Martin, J., Jiang, H., Bernin, D., Forssell-Aronsson, E., Laun, F., Sierra, A., & Topgaard, D. (2025). Frequency-dependence in multidimensional diffusion–relaxation correlation MRI of the brain: Overfitting or meaningful parameter?. Imaging Neuroscience, 3. https://doi.org/10.1162/imag.a.143

Vancouver

Yon M, Narvaez O, Martin J, Jiang H, Bernin D, Forssell-Aronsson E, et al. Frequency-dependence in multidimensional diffusion–relaxation correlation MRI of the brain: Overfitting or meaningful parameter?. Imaging Neuroscience. 2025;3. doi:10.1162/imag.a.143

BibTeX
@article{Yon2025,
  author = {Yon, Maxime and Narvaez, Omar and Martin, Jan and Jiang, Hong and Bernin, Diana and Forssell-Aronsson, Eva and Laun, Frederik and Sierra, Alejandra and Topgaard, Daniel},
  title = {Frequency-dependence in multidimensional diffusion–relaxation correlation MRI of the brain: Overfitting or meaningful parameter?},
  journal = {Imaging Neuroscience},
  year = {2025},
  volume = {3},
  doi = {10.1162/imag.a.143}
}
Kostenlos starten →