Biophysical simulations of fMRI responses using realistic microvascular models: Insights into distinct hemodynamics in humans and mice
Imaging Neuroscience · 2026
DOI: 10.1162/imag.a.1340 ↗Kurz gefasst
Fachartikel in der Zeitschrift Imaging Neuroscience, 2026. Verfasst von Grant Hartung und 5 weiteren Autor:innen. Beteiligte Einrichtung: Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, United States. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Hemodynamics, Microvessels, Cerebrovascular Circulation. Die Arbeit nennt 103 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, NINDS NIH HHS, NIMH NIH HHS.
Abstract (Originalsprache)
Functional magnetic resonance imaging (fMRI) is broadly used to measure human brain activity, however, the hemodynamic changes that comprise the fMRI response to neuronal activity are often interpreted using microscopy data in mice. These microscopy data provide ground-truth observations of how individual blood vessels respond to neuronal activity and thus form the basis of our fundamental understanding of neurovascular coupling. Although these invasive experiments provide invaluable insight, there are striking differences in the vascular architecture of mouse and human brains that may influence the hemodynamic response. Motivated by this, we developed a biophysical modeling framework for realistic hemodynamic simulations in both mouse and human cerebral cortex. For this, we utilized Vascular Anatomical Network (VAN) models that explicitly represent the full microvascular tree as a single connected network, originally based on anatomical reconstructions from a given location of mouse cerebral cortex. We extended the VAN modeling framework using synthetic VAN models representing the microvascular network at a single location of the human cerebral cortex. To account for larger size and complexity of the human VAN models, we developed an efficient computational framework to simulate the full hemodynamic responses in this human model and compared the simulated fMRI responses between mice and humans. Our biophysical simulations are based entirely on first principles (e.g., conservation of mass); model parameter values were fixed across all simulations, not tuned to fit data, as they represent meaningful physical constants taken from previous measurements. Only two simple calibrations were tuned for each simulation, to match baseline perfusion rates (blood flow) and oxygen extraction (OEF). Our results show that differences in microvasculature indeed influenced the hemodynamic response and led to observable differences in timing—for example, the simulated fMRI response peak in humans was delayed by ~2 s compared with that of mice, consistent with prior fMRI observations. While there are many known differences in vascular architecture in rodents and humans, we also discovered that, unexpectedly, an asymmetry in the number of branches of the penetrating intracortical arterioles and venules appears to be conserved across species. We demonstrate through further simulations that this anatomical property may also be needed for suitable hemodynamic responses. Our framework thus provides a valuable tool for bridging in-vivo microscopy of microvascular dynamics to human fMRI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, United States.
- Department of Radiology, Harvard Medical School, Boston, MA, United States.
- Department of Physics, Carleton University, Ottawa, ON, Canada.
- Institute of Mental Health Research, Royal Ottawa Mental Health Centre, Ottawa, ON, Canada.
- Department of Bioengineering, University of Illinois at Chicago, Chicago, IL, United States.
- Department of Neurosurgery, University of Illinois at Chicago, Chicago, IL, United States.
ORCID-Profile: Grant Hartung, Jonathan R Polimeni
Förderung
- NIBIB NIH HHS
- NINDS NIH HHS
- NIMH NIH HHS
- National Institute of Biomedical Imaging and Bioengineering
- National Institute of Mental Health
- National Institute of Neurological Disorders and Stroke
- Canadian Institutes of Health Research
Zitieren
APA
Hartung, G., Berman, A. J. L., Sakadžić, S., Linninger, A., Boas, D. A., & Polimeni, J. R. (2026). Biophysical simulations of fMRI responses using realistic microvascular models: Insights into distinct hemodynamics in humans and mice. Imaging Neuroscience. https://doi.org/10.1162/imag.a.1340
Vancouver
Hartung G, Berman AJL, Sakadžić S, Linninger A, Boas DA, Polimeni JR. Biophysical simulations of fMRI responses using realistic microvascular models: Insights into distinct hemodynamics in humans and mice. Imaging Neuroscience. 2026. doi:10.1162/imag.a.1340
BibTeX
@article{Hartung2026,
author = {Hartung, Grant and Berman, Avery J L and Sakadžić, Sava and Linninger, Andreas and Boas, David A and Polimeni, Jonathan R},
title = {Biophysical simulations of fMRI responses using realistic microvascular models: Insights into distinct hemodynamics in humans and mice},
journal = {Imaging Neuroscience},
year = {2026},
doi = {10.1162/imag.a.1340}
}
EUVIMED