EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Non-invasive MRI of choroid plexus vascular function

Peiying Liu iD, Lori Donaldson, Beini Hu, Gagan S Wig, Hanzhang Lu

Imaging Neuroscience · 17.04.2026 · 4

DOI: 10.1162/imag.a.1216 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Imaging Neuroscience, online erschienen am 17.04.2026. Verfasst von Peiying Liu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic Radiology & Nuclear Medicine, University of Maryland School of Medicine, Baltimore, MD, United States. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Institute of Neurological Disorders and Stroke, National Institute of Biomedical Imaging and Bioengineering.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Choroid plexus (ChP) is a highly vascularized tissue in the ventricles of the brain, and it plays an important role in the production of cerebrospinal fluid (CSF) and formation of the blood-CSF barrier. The function of ChP vessels has been implicated in waste clearance efficiency during aging and neurodegenerative diseases. At present, postmortem studies are the main method to assess choroid plexus vascular integrity, with a few tools to measure ChP function in living humans. Here, we proposed a non-invasive MRI approach to assess ChP vascular elasticity based on the detection of MRI signal changes in response to vasoactive challenges. The mechanism of the signal is hypothesized to be due to reciprocal blood and stroma volume alterations during vessel expansion. We demonstrated that ChP vascular elasticity can be evaluated with BOLD MRI using a hypercapnia challenge of CO2 inhalation. This effect is specifically located in the brain ventricles where ChP is abundant. We revealed the ability of the technique in detecting age-related reduction in ChP vascular elasticity. We further showed that this effect can be assessed with gas-free methods, including intermittent breath modulation and resting-state BOLD fMRI. We characterized the image contrast requirement under which this effect can be detected. This technique may provide a clinically feasible tool for assessing ChP vascular function in health and disease.

Schlagwörter

Stichwörter der Autor:innen

BOLDagingchoroid plexuselasticityfunctional MRIvasculature

Autor:innen und Institutionen

  • Department of Diagnostic Radiology & Nuclear Medicine, University of Maryland School of Medicine, Baltimore, MD, United States.
  • Center for Vital Longevity & Department of Psychology, The University of Texas at Dallas, Dallas, TX, United States.
  • Department of Psychiatry, The University of Texas Southwestern Medical Center, Dallas, TX, United States.
  • The Russell H. Morgan Department of Radiology & Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, United States.

ORCID-Profile: Peiying Liu

Förderung

  • National Institute of Neurological Disorders and Stroke
  • National Institute of Biomedical Imaging and Bioengineering

Zitieren

APA

Liu, P., Donaldson, L., Hu, B., Wig, G. S., & Lu, H. (2026). Non-invasive MRI of choroid plexus vascular function. Imaging Neuroscience, 4. https://doi.org/10.1162/imag.a.1216

Vancouver

Liu P, Donaldson L, Hu B, Wig GS, Lu H. Non-invasive MRI of choroid plexus vascular function. Imaging Neuroscience. 2026;4. doi:10.1162/imag.a.1216

BibTeX
@article{Liu2026,
  author = {Liu, Peiying and Donaldson, Lori and Hu, Beini and Wig, Gagan S and Lu, Hanzhang},
  title = {Non-invasive MRI of choroid plexus vascular function},
  journal = {Imaging Neuroscience},
  year = {2026},
  volume = {4},
  doi = {10.1162/imag.a.1216}
}
Kostenlos starten →