EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Towards a 384-channel magnetoencephalography system based on optically pumped magnetometers

Holly Schofield, Ryan M Hill, Lukas Rier, Ewan Kennett, Gonzalo Reina Rivero, Joseph Gibson, Ashley Tyler, Zoe Tanner, Frank Worcester, Tyler Hayward, James Osborne, Cody Doyle und 4 weitere

Imaging Neuroscience · 23.12.2025 · 3

DOI: 10.1162/imag.a.1042 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Imaging Neuroscience, online erschienen am 23.12.2025. Verfasst von Holly Schofield und 15 weiteren Autor:innen. Beteiligte Einrichtung: Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, United Kingdom. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIMH NIH HHS, Engineering and Physical Sciences Research Council, EPSRC.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Magnetoencephalography using optically pumped magnetometers (OPM-MEG) is gaining traction as a neuroimaging tool, with potential for improved performance and practicality compared with conventional instrumentation. However, OPM-MEG has so far lagged conventional-MEG in terms of the number of independent measurements of the MEG signal that can be made across the scalp (i.e., the number of channels). This is important since increasing the channel count offers improvements in sensitivity, spatial resolution, and coverage. Unfortunately, increasing channel count also poses significant technical and practical challenges. Here, we describe a new OPM-MEG system which exploits 3-axis sensors and integrated miniaturised electronic control units to measure MEG data from up to 384 channels. We also introduce a high-speed calibration method to ensure that the fields measured are high fidelity. We initially validate this system using a phantom: specifically, we localise a set of magnetic dipoles and compare the MEG-derived distances between them with the ground truth, demonstrating an accuracy of ~1 mm. We further show that the correlation between a mathematical model of the phantom and the magnetic fields measured is >0.998. Secondly, we demonstrate utility of our system for human MEG acquisition. Via measurement of visual cortex activity, we demonstrate improvements in sensitivity afforded by a higher channel count, and via a movie-watching experiment we show increased spatial resolution. In sum, we report the first OPM-MEG system with a channel count larger than that of typical conventional MEG devices. This represents a significant step towards OPMs becoming the sensor of choice for MEG.

Schlagwörter

Stichwörter der Autor:innen

imaging hardwaremagnetoencephalography (MEG)optically pumped magnetometer (OPM)

Autor:innen und Institutionen

  • Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham, United Kingdom.
  • Cerca Magnetics Limited, Nottingham, United Kingdom.
  • QuSpin Inc., Louisville, CO, United States.

Förderung

  • NIMH NIH HHS
  • Engineering and Physical Sciences Research Council
  • EPSRC
  • Medical Research Council

Zitieren

APA

Schofield, H., Hill, R. M., Rier, L., Kennett, E., Rivero, G. R., Gibson, J., Tyler, A., Tanner, Z., Worcester, F., Hayward, T., Osborne, J., Doyle, C., Shah, V., Boto, E., Holmes, N., & Brookes, M. J. (2025). Towards a 384-channel magnetoencephalography system based on optically pumped magnetometers. Imaging Neuroscience, 3. https://doi.org/10.1162/imag.a.1042

Vancouver

Schofield H, Hill RM, Rier L, Kennett E, Rivero GR, Gibson J, et al. Towards a 384-channel magnetoencephalography system based on optically pumped magnetometers. Imaging Neuroscience. 2025;3. doi:10.1162/imag.a.1042

BibTeX
@article{Schofield2025,
  author = {Schofield, Holly and Hill, Ryan M and Rier, Lukas and Kennett, Ewan and Rivero, Gonzalo Reina and Gibson, Joseph and Tyler, Ashley and Tanner, Zoe and Worcester, Frank and Hayward, Tyler and Osborne, James and Doyle, Cody and Shah, Vishal and Boto, Elena and Holmes, Niall and Brookes, Matthew J},
  title = {Towards a 384-channel magnetoencephalography system based on optically pumped magnetometers},
  journal = {Imaging Neuroscience},
  year = {2025},
  volume = {3},
  doi = {10.1162/imag.a.1042}
}
Kostenlos starten →