EUVIMEDEUVIMED entdecken
Open Access

Effects of different blood storage conditions on leukocytes cell population data using the Sysmex XN hematological analyzer

Vincenzo Roccaforte, Rossella Panella, Massimo Daves, Antonella De Martino, Erika Jani, Giovanni Sabbatini, Pierfrancesco Agostini, Floriana De Filippi, Paolo Formenti, Giuseppe Lippi, Matteo Vidali, Angelo Pezzi und 1 weitere

Biochemia medica · 15.06.2026 · 36 (2) · 289-301

DOI: 10.11613/bm.2026.020704 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biochemia medica, online erschienen am 15.06.2026. Verfasst von Vincenzo Roccaforte und 12 weiteren Autor:innen. Beteiligte Einrichtung: S.C. Analisi Chimico Cliniche e Microbiologiche, ASST Nord Milano, Ospedale Bassini, Cinisello Balsamo, Italy. Hauptthemen laut MEDLINE: Leukocytes, Blood Preservation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 13 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The aim of this study was to investigate the stability of leukocyte cell population data (CPD) assessed on Sysmex XN-3000 hematological analyzer in samples stored for up to 24 h at different temperatures. Materials and methods: Whole-blood samples from 25 donors were analyzed for 18 CPD parameters at baseline and after storage at room temperature (RT), 4 °C, or 37 °C for 3, 6, 12, and 24 h. Stability was assessed using three complementary approaches: paired Wilcoxon tests with Bonferroni correction, percent difference between medians >10%, and per-sample percent change >10% in ≥2 samples. In addition, the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) stability protocol was applied, modelling percent differences over time using linear regression through the origin to estimate the rate of change and the stability limit (SL), defined as the time required to exceed a maximum permissible error of 10%.

Results

According to predefined stability criteria, several CPD parameters exceeded stability limits within 24 h, particularly under storage at 37 °C. Parameters related to neutrophil, lymphocyte and monocyte complexity and size (e.g., neutrophils complexity (NE-SSC), neutrophils size (NE-FSC), monocytes complexity (MO-X), lymphocytes complexity (LY-X); where SSC = side scatter, FSC = forward scatter) showed slow rates of change with estimated stability limits beyond 24 h across storage conditions. In contrast, fluorescence- and dispersion-related parameters (e.g., neutrophils fluorescence intensity (NE-SFL), width of dispersion of neutrophils complexity (NE-WX), width of dispersion of lymphocytes fluorescence (LY-WY), width of dispersion of monocytes size (MO-WZ); where SFL = side fluorescence, W = width of dispersion) reached the stability limit within 24 h, most frequently at 37 °C. Lymphocyte size (LY-Z) exceeded the stability limit at 17 h also under storage at 4 °C.

Conclusions

Leukocyte CPD stability is strongly temperature- and parameter-dependent. Exposure to elevated temperature (37 °C) leads to early exceedance of predefined stability limits for several CPD parameters, whereas storage at room temperature preserves stability for longer time intervals. Avoiding prolonged exposure to high temperatures is therefore essential for reliable CPD assessment in routine laboratory practice.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LeukocytesBlood PreservationHumansTemperatureLeukocyte CountTime FactorsNeutrophils

Stichwörter der Autor:innen

Sysmexcell population data (CPD)experimental hematology parameterspre-analytical variabilitysample stability

Autor:innen und Institutionen

  • S.C. Analisi Chimico Cliniche e Microbiologiche, ASST Nord Milano, Ospedale Bassini, Cinisello Balsamo, Italy.
  • UOSVD Patologia Clinica, ASL Bari, Ospedale San Paolo, Bari, Italy.
  • Laboratory of Clinical Biochemistry (SABES-ASDAA), Hospital of Bolzano, Bolzano, Italy.
  • S.C. Anestesia, Rianimazione e Terapia Intensiva, ASST Nord Milano, Ospedale Bassini, Cinisello Balsamo, Italy.
  • Section of Clinical Biochemistry, University of Verona, Verona, Italy.
  • Clinical Pathology Unit, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.

Zitieren

APA

Roccaforte, V., Panella, R., Daves, M., De Martino, A., Jani, E., Sabbatini, G., Agostini, P., De Filippi, F., Formenti, P., Lippi, G., Vidali, M., Pezzi, A., & Pastori, S. (2026). Effects of different blood storage conditions on leukocytes cell population data using the Sysmex XN hematological analyzer. Biochemia medica, 36(2), 289-301. https://doi.org/10.11613/bm.2026.020704

Vancouver

Roccaforte V, Panella R, Daves M, De Martino A, Jani E, Sabbatini G, et al. Effects of different blood storage conditions on leukocytes cell population data using the Sysmex XN hematological analyzer. Biochemia medica. 2026;36(2):289-301. doi:10.11613/bm.2026.020704

BibTeX
@article{Roccaforte2026,
  author = {Roccaforte, Vincenzo and Panella, Rossella and Daves, Massimo and De Martino, Antonella and Jani, Erika and Sabbatini, Giovanni and Agostini, Pierfrancesco and De Filippi, Floriana and Formenti, Paolo and Lippi, Giuseppe and Vidali, Matteo and Pezzi, Angelo and Pastori, Stefano},
  title = {Effects of different blood storage conditions on leukocytes cell population data using the Sysmex XN hematological analyzer},
  journal = {Biochemia medica},
  year = {2026},
  volume = {36},
  number = {2},
  pages = {289--301},
  doi = {10.11613/bm.2026.020704}
}
Kostenlos starten →