EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access

Analysis of serum homocysteine in the laboratory practice - comparison of the direct chemiluminescence immunoassay and high performance liquid chromatography coupled with fluorescent detection

Łukasz Paprotny, Dorota Wianowska, Magdalena Izdebska, Agnieszka Celejewska, Dorota Szewczak, Janusz Solski

Biochemia medica · 15.10.2020 · 30 (3) · 439-445

DOI: 10.11613/bm.2020.030703 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Biochemia medica, online erschienen am 12.10.2020. Verfasst von Łukasz Paprotny und 5 weiteren Autor:innen. Beteiligte Einrichtung: Research and Development Center, Alab Laboratories, Lublin, Poland. Die Arbeit wurde bisher 27-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Effective diagnosis of cardiovascular diseases requires the right tools to be used enabling selective and sensitive analysis of their biomarkers. One of them is homocysteine (Hcy), nowadays determined by immunoassays and chromatographic methods. This study aims to compare the results obtained by direct chemiluminescence immunoassay (CLIA) and high performance liquid chromatography with fluorescent detection (HPLC-FD) using commercial kits. Materials and methods: Homocysteine concentration was determined in serum samples obtained from 101 individuals, using Atellica IM HCY (Siemens Healthineers, Erlangen, Germany) and HCY in plasma/serum – HPLC-FD (Chromsystems Instruments & Chemicals GmbH, Gräfelfing, Germany) tests validated for routine analysis. The latter was applied as a reference method. The comparability and agreement between the tested methods were evaluated using the Passing-Bablok (PB) regression analysis and the Bland-Altman (BA) method of the differences analysis.

Results

Studies showed that CLIA gives higher Hcy concentrations (15.7 ± 4.14 μmol/L). Passing-Bablok regression analysis of the results obtained with CLIA (y) compared with HPLC-FD (x) yielded an intercept of 0.22 (95%CI: - 2.16 to 2.46) and slope of 1.58 (95%CI: 1.33 to 1.87). Bland-Altman analysis demonstrated a systematic positive bias for CLIA of 5.85 ± 2.77 μmol/L.

Conclusions

Methods disagreement precludes their interchangeability. Lower Hcy values by HPLC-FD result from its greater selectivity. High performance liquid chromatography with fluorescent detection should be considered as preferential method for analysing Hcy in blood serum as well as the recommended reference method for routine clinical analysis. This fact, however, imposes the need to establish new reference ranges.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AdultCardiovascular DiseasesChromatography, High Pressure LiquidFemaleHomocysteineHumansImmunoassayLuminescent MeasurementsMaleReagent Kits, DiagnosticRegression AnalysisSpectrometry, Fluorescence

Stichwörter der Autor:innen

homocysteineimmunoassayliquid chromatographyluminescent measurements

Substanzen

Reagent Kits, DiagnosticHomocysteine

Autor:innen und Institutionen

  • Research and Development Center, Alab Laboratories, Lublin, Poland.
  • Department of Chromatographic Methods, Faculty of Chemistry, Maria Curie-Skłodowska University, Lublin, Poland.
  • Department of Laboratory Diagnostics, Medical University of Lublin, Lublin, Poland.

Zitieren

APA

Paprotny, Ł., Wianowska, D., Izdebska, M., Celejewska, A., Szewczak, D., & Solski, J. (2020). Analysis of serum homocysteine in the laboratory practice - comparison of the direct chemiluminescence immunoassay and high performance liquid chromatography coupled with fluorescent detection. Biochemia medica, 30(3), 439-445. https://doi.org/10.11613/bm.2020.030703

Vancouver

Paprotny Ł, Wianowska D, Izdebska M, Celejewska A, Szewczak D, Solski J. Analysis of serum homocysteine in the laboratory practice - comparison of the direct chemiluminescence immunoassay and high performance liquid chromatography coupled with fluorescent detection. Biochemia medica. 2020;30(3):439-445. doi:10.11613/bm.2020.030703

BibTeX
@article{Paprotny2020,
  author = {Paprotny, Łukasz and Wianowska, Dorota and Izdebska, Magdalena and Celejewska, Agnieszka and Szewczak, Dorota and Solski, Janusz},
  title = {Analysis of serum homocysteine in the laboratory practice - comparison of the direct chemiluminescence immunoassay and high performance liquid chromatography coupled with fluorescent detection},
  journal = {Biochemia medica},
  year = {2020},
  volume = {30},
  number = {3},
  pages = {439--445},
  doi = {10.11613/bm.2020.030703}
}
Kostenlos starten →