Abstract 839: Comparative Audit Of Deterministic-Augmented AI Versus Retrieval-Augmented Generation In Acute Ischemic Stroke Decision Support

M. F. Stiefel, D. C. Stiefel

Stroke: Vascular and Interventional Neurology · 18.10.2026 · 6 (Suppl_1)

DOI: 10.1161/svi270000_839 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Stroke: Vascular and Interventional Neurology, erschienen am 18.10.2026. Verfasst von M. F. Stiefel und 1 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction/Purpose: Healthcare-dedicated AI clinical decision support platforms — the deterministic-augmented AI (DAA) system MedSync, and three retrieval-augmented generation (RAG) platforms (OpenEvidence Standard, OE Deep Consult, ChatGPT for Clinicians) — are increasingly used for patient care. The two architectures differ fundamentally: RAG platforms retrieve from a document corpus and emit free-text recommendations, whereas the DAA system routes structurally to specific guideline sections with page-cited recommendations. We evaluated their operational faithfulness to the 2026 AHA Stroke Guidelines. Materials/Methods: Twenty acute ischemic stroke vignettes spanning the IVT/EVT decision range — wake-up and late-window thrombolysis, minor-but-disabling deficits, pediatric stroke, large vessel occlusion with bridging, M2 and basilar thrombectomy, late-window thrombectomy, anticoagulant exposure, and post-craniotomy contraindications — were submitted verbatim to each platform (80 case-platform decisions). Operational faithfulness (bedside reliability) required three conditions: Correct Direction (right treatment); Correct Strength Calibration (language aligned with AHA/ACC Class: "is recommended" vs "is reasonable"); and Reasoning Framework Currency (reasoning aligned with current 2026 standards). RAG failures were classified using a four-pattern taxonomy: Legacy Guideline Use, Reference-Reasoning Mismatch, Governing Document Disparity, and Reference Misattribution.

Results

Deterministic-AI was operationally faithful in 20 of 20 cases (100%); OE Deep Consult in 12 of 20 (60%); ChatGPT for Clinicians in 8 of 20 (40%); OE Standard in 6 of 20 (30%). The three conditions degraded in cascade: the RAG platforms were direction-correct in 90-95% of cases, strength-aligned in 50-70%, and reasoning-current in only 30-60% — converging on the right answer while diverging from the current framework in language and logic. Recurrent reasoning failures included the superseded 2018 0-3/3-4.5-hour thrombolysis subdivision, the outdated 3-month post-craniotomy exclusion, DAWN/DEFUSE-3 imaging criteria applied as gates the 2026 guideline has broadened, and the pre-2026 single-Class-IIb M2 thrombectomy framework; in thrombectomy-primary cases, OE Standard and ChatGPT were operationally faithful in 0 of 5. One RAG response inverted direction entirely, recommending antiplatelet therapy over thrombolysis for a disabling minor stroke. MedSync used native 2026 section routing, page-cited recommendations, and forced clinician judgment (e.g., gated disabling-status determination), rendering correct direction, strength, and reasoning on every case. OE Standard most often anchored to older AHA guidelines or to specialty-society documents instead of the 2026 guideline (Governing Document Disparity). OE Deep Consult cited the 2026 guideline in 85% of responses but applied pre-2026 frameworks in 45% (Reference-Reasoning Mismatch). ChatGPT cited the canonical 2026 publication in 5 of 20 responses (25%) and drew from surrogate AHA-attributed documents in 12 of 20 cases (60%, Reference Misattribution). Failure-pattern instances totaled 21 (OE Standard), 22 (OE Deep Consult), and 26 (ChatGPT), versus 0 for MedSync.

Conclusion

MedSync — anchored to current 2026 routing — achieved 100% operational faithfulness. Despite retrieval access to the new stroke guidelines, the three RAG platforms failed in 40-70% of cases, and citing the current guideline did not ensure applying it. Because these failures occur beneath a correct-sounding verdict, they are largely invisible to the bedside user. A system that produces the right answer through the wrong reasoning is not a tool physicians can trust at the bedside; deterministic architectures that preserve clinician judgment are.

Zitieren

APA

Stiefel, M. F., & Stiefel, D. C. (2026). Abstract 839: Comparative Audit Of Deterministic-Augmented AI Versus Retrieval-Augmented Generation In Acute Ischemic Stroke Decision Support. Stroke: Vascular and Interventional Neurology, 6(Suppl_1). https://doi.org/10.1161/svi270000_839

Vancouver

Stiefel MF, Stiefel DC. Abstract 839: Comparative Audit Of Deterministic-Augmented AI Versus Retrieval-Augmented Generation In Acute Ischemic Stroke Decision Support. Stroke: Vascular and Interventional Neurology. 2026;6(Suppl_1). doi:10.1161/svi270000_839

BibTeX
@article{Stiefel2026,
  author = {Stiefel, M. F. and Stiefel, D. C.},
  title = {Abstract 839: Comparative Audit Of Deterministic-Augmented AI Versus Retrieval-Augmented Generation In Acute Ischemic Stroke Decision Support},
  journal = {Stroke: Vascular and Interventional Neurology},
  year = {2026},
  volume = {6},
  number = {Suppl_1},
  doi = {10.1161/svi270000_839}
}
Kostenlos starten →