Abstract 1478: CT Perfusion Software Variability And Its Impact On Thrombectomy Eligibility

M. Ali, N. Ali, M. M. Elsayed, A. Elsayed

Stroke: Vascular and Interventional Neurology · 18.10.2026 · 6 (Suppl_1)

DOI: 10.1161/svi270000_1478 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Stroke: Vascular and Interventional Neurology, erschienen am 18.10.2026. Verfasst von M. Ali und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction/Purpose: Automated computed tomography perfusion (CTP) software is central to endovascular thrombectomy (EVT) patient selection, yet multiple commercial platforms (RAPID, Viz.ai, e-CTP/Brainomix, Olea, Syngo.via, MIStar, F-STROKE, Minerva, IntelliSpace Portal) use distinct post-processing algorithms and thresholds. Whether platform choice meaningfully alters ischemic-core and penumbra quantification and consequently EVT eligibility remains incompletely defined. We synthesized comparative evidence evaluating inter-software agreement in perfusion-based core/penumbra estimation and its downstream effect on thrombectomy candidacy. Materials/Methods: We reviewed published head-to-head comparative studies in which two or more automated CTP platforms were applied to the same patient dataset to derive ischemic-core and penumbra volumes, with agreement assessed via intraclass correlation coefficients (ICC), Bland-Altman limits, Pearson/Spearman correlation, and kappa statistics for binary EVT-eligibility concordance (e.g., DEFUSE-3-type criteria, rCBF/Tmax thresholds). Studies spanned single-center and multicenter cohorts, several validated against follow-up infarct volume on MRI-DWI. Results: Across pooled comparisons, absolute core-volume agreement with RAPID varied substantially by platform: F-STROKE showed the closest concordance (ICC 0.97 for core, 0.84 for penumbra), while Syngo.via showed the weakest (ICC 0.77 core, 0.66 penumbra), tending to overestimate core and underestimate penumbra. Binary EVT-eligibility concordance mirrored this pattern, ranging from excellent for F-STROKE (kappa 0.84-0.90) and good for MIStar (kappa 0.71-0.88) to poor for Syngo.via (kappa 0.20-0.41), the latter yielding overly restrictive candidate selection. A three-platform comparison (RAPID, Viz.ai, e-CTP) found substantial-to-excellent agreement for rCBF30% and Tmax>6s maps (ρ 0.67-0.81) and comparable final-infarct-volume prediction across all three. A multicenter comparison of Olea versus RAPID found significantly different mean core volumes (18.7 vs 10.5 mL, p

Zitieren

APA

Ali, M., Ali, N., Elsayed, M. M., & Elsayed, A. (2026). Abstract 1478: CT Perfusion Software Variability And Its Impact On Thrombectomy Eligibility. Stroke: Vascular and Interventional Neurology, 6(Suppl_1). https://doi.org/10.1161/svi270000_1478

Vancouver

Ali M, Ali N, Elsayed MM, Elsayed A. Abstract 1478: CT Perfusion Software Variability And Its Impact On Thrombectomy Eligibility. Stroke: Vascular and Interventional Neurology. 2026;6(Suppl_1). doi:10.1161/svi270000_1478

BibTeX
@article{Ali2026,
  author = {Ali, M. and Ali, N. and Elsayed, M. M. and Elsayed, A.},
  title = {Abstract 1478: CT Perfusion Software Variability And Its Impact On Thrombectomy Eligibility},
  journal = {Stroke: Vascular and Interventional Neurology},
  year = {2026},
  volume = {6},
  number = {Suppl_1},
  doi = {10.1161/svi270000_1478}
}
Kostenlos starten →