Abstract 1398: CTA-Negative Subarachnoid Hemorrhage From A Basilar Blister Pseudoaneurysm: Staged Endovascular Reconstruction

R. A. Mojica Castillo, R. M. Teran-Mejia, E. Lin

Stroke: Vascular and Interventional Neurology · 18.10.2026 · 6 (Suppl_1)

DOI: 10.1161/svi270000_1398 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Stroke: Vascular and Interventional Neurology, erschienen am 18.10.2026. Verfasst von R. A. Mojica Castillo und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction/Purpose: Basilar artery blister pseudoaneurysms are exceptionally rare, fragile, non-saccular lesions arising from non-branching arterial segments and may be occult on computed tomography angiography (CTA). Their shallow morphology and posterior circulation location create substantial diagnostic and therapeutic challenges. We report a ruptured mid-basilar blister pseudoaneurysm diagnosed after serial angiography and treated with staged overlapping stent reconstruction. Materials/Methods: Single-patient case report based on retrospective review of the clinical course, serial neuroimaging, cerebral angiography, endovascular procedures, and neurological outcome during the index hospitalization.

Results

A 71-year-old man with hypertension presented with thunderclap headache and encephalopathy (Glasgow Coma Scale 14, Hunt-Hess grade 3, modified Fisher grade 4). Noncontrast head CT demonstrated diffuse basal cisternal subarachnoid hemorrhage with intraventricular extension and obstructive hydrocephalus requiring external ventricular drain placement. CTA showed no definitive aneurysm. Initial digital subtraction angiography (DSA) on hospital day 1 demonstrated only a subtle rightward-facing mid-basilar wall outpouching suspicious for a blister lesion; because its morphology remained indeterminate, treatment was deferred. Repeat DSA on hospital day 6 confirmed a broad, shallow pseudoaneurysm arising from the right sidewall of the mid-superior basilar artery, measuring 6.2 mm in width, 1.24 mm in height, and 6.2 mm at the neck, with Raymond-Roy class III filling. Parent-vessel reconstruction was performed with a 3×18-mm LVIS EVO braided intracranial stent under dual antiplatelet therapy. Follow-up DSA on hospital day 20 demonstrated a patent construct without in-stent stenosis but persistent Raymond-Roy class III filling, prompting deployment of an overlapping 3×15-mm Neuroform Atlas stent to augment flow remodeling and wall apposition. The hospital course was complicated by cerebral vasospasm managed with nimodipine, hemodynamic optimization, and serial transcranial Doppler monitoring, without new territorial infarction. The patient was discharged on dual antiplatelet therapy with an NIHSS score of 1 and modified Rankin Scale score of 2.

Conclusion

Ruptured basilar blister pseudoaneurysms may remain occult on CTA and equivocal on initial catheter angiography despite an aneurysmal-pattern subarachnoid hemorrhage. Persistent diagnostic suspicion and early repeat DSA can be decisive for lesion characterization and treatment planning. In this case, staged overlapping stent reconstruction preserved the parent artery while addressing persistent aneurysm filling and was associated with a favorable early neurological and functional outcome. This case highlights the value of serial angiographic reassessment and individualized reconstructive treatment for these rare, technically challenging lesions.

Zitieren

APA

Castillo, R. A. M., Teran-Mejia, R. M., & Lin, E. (2026). Abstract 1398: CTA-Negative Subarachnoid Hemorrhage From A Basilar Blister Pseudoaneurysm: Staged Endovascular Reconstruction. Stroke: Vascular and Interventional Neurology, 6(Suppl_1). https://doi.org/10.1161/svi270000_1398

Vancouver

Castillo RAM, Teran-Mejia RM, Lin E. Abstract 1398: CTA-Negative Subarachnoid Hemorrhage From A Basilar Blister Pseudoaneurysm: Staged Endovascular Reconstruction. Stroke: Vascular and Interventional Neurology. 2026;6(Suppl_1). doi:10.1161/svi270000_1398

BibTeX
@article{Castillo2026,
  author = {Castillo, R. A. Mojica and Teran-Mejia, R. M. and Lin, E.},
  title = {Abstract 1398: CTA-Negative Subarachnoid Hemorrhage From A Basilar Blister Pseudoaneurysm: Staged Endovascular Reconstruction},
  journal = {Stroke: Vascular and Interventional Neurology},
  year = {2026},
  volume = {6},
  number = {Suppl_1},
  doi = {10.1161/svi270000_1398}
}
Kostenlos starten →