Introduction
Carotid angioplasty and stenting (CAS) has evolved to improve plaque containment through refined stent designs and to reduce distal embolization using adjunctive proximal and distal embolic protection strategies. Despite these advances, clinically silent embolization remains common and is detectable as new diffusion-weighted imaging (DWI) lesions, which may be associated with cognitive decline and subsequent cerebrovascular events. The Neuroguard integrated embolic protection (IEP; Medtronic, Dublin, Ireland) system combines a stent, angioplasty balloon, and embolic filter into a single device, streamlining CAS while potentially enhancing embolic protection through 40-µm filter pores that may more effectively reduce cerebral embolic burden than conventional systems.
Methods
We retrospectively identified adults undergoing primary CAS with the Neuroguard-IEP and routine post-stenting MRI from January to December 2025. Patients received either Neuroguard-IEP alone or Neuroguard-IEP with adjunctive distal embolic protection (dEPD). New ipsilateral DWI lesions were recorded and volumetrically estimated using spherical approximation. Both unmatched and case-control matched analyses were carried out to assess lesion burden and correlation with clinical outcomes.
Results
We included 42 patients (median age 71 years [IQR 65.3-74.8]; 38.1% women). Neuroguard IEP alone was used in 29 patients, and adjunctive dEPD in 13. Post-stenting MRI identified new ipsilateral DWI-positive lesions in 10 patients, all clinically silent and similar between cohorts (24.1% vs 23.1%, p>0.99). Lesion burden did not differ, including solitary (13.8% vs 15.4%) or multiple lesions (10.3% vs 7.7%) and lesion volume (116 mm³ [IQR 68-358] vs 119 mm³ [93-333], p=0.83). Findings remained unchanged after case-control matching. Clinical follow-up was available in 95.2% at 30 days, 61.9% at 90 days, and 9.5% at 6 months. No disabling or non-disabling strokes occurred; one non-disabling TIA occurred in the adjunctive dEPD group within 12 months.
Conclusion
Use of the NeuroGuard IEP system during CAS was associated with a low incidence of new, clinically silent DWI-positive lesions, with no apparent incremental benefit from adjunctive dEPD. Combined with proximal balloon-mediated flow reversal, the system demonstrated procedural safety. Larger studies are needed to confirm efficacy and long-term clinical impact.
Zitieren
APA
JAIKUMAR, V., Patel, D., Gottipati, A., Goyal, A., Siddiqi, N., Leasher, E., Przepiorka, L., Rifkin, L., Wahlig, P., Lim, J., Lai, R., Davies, J., Snyder, K. V., Levy, E. I., & Siddiqui, A. H. (2026). Abstract 1287: Role of Integrated Embolic Protection Systems in Carotid Angioplasty and Stenting Under Balloon-Guided Proximal Embolic Protection: A Case-Controlled Matched Analysis. Stroke: Vascular and Interventional Neurology, 6(Suppl_1). https://doi.org/10.1161/svi270000_1287
Vancouver
JAIKUMAR V, Patel D, Gottipati A, Goyal A, Siddiqi N, Leasher E, et al. Abstract 1287: Role of Integrated Embolic Protection Systems in Carotid Angioplasty and Stenting Under Balloon-Guided Proximal Embolic Protection: A Case-Controlled Matched Analysis. Stroke: Vascular and Interventional Neurology. 2026;6(Suppl_1). doi:10.1161/svi270000_1287
BibTeX
@article{JAIKUMAR2026,
author = {JAIKUMAR, V. and Patel, D. and Gottipati, A. and Goyal, A. and Siddiqi, N. and Leasher, E. and Przepiorka, L. and Rifkin, L. and Wahlig, P. and Lim, J. and Lai, R. and Davies, J. and Snyder, K. V. and Levy, E. I. and Siddiqui, A. H.},
title = {Abstract 1287: Role of Integrated Embolic Protection Systems in Carotid Angioplasty and Stenting Under Balloon-Guided Proximal Embolic Protection: A Case-Controlled Matched Analysis},
journal = {Stroke: Vascular and Interventional Neurology},
year = {2026},
volume = {6},
number = {Suppl_1},
doi = {10.1161/svi270000_1287}
}
EUVIMED