Abstract 1191: When AI Misses: Perfusion Characteristics Associated With Large Vessel Occlusion Detection
Stroke: Vascular and Interventional Neurology · 18.10.2026 · 6 (Suppl_1)
DOI: 10.1161/svi270000_1191 ↗Kurz gefasst
Fachartikel in der Zeitschrift Stroke: Vascular and Interventional Neurology, erschienen am 18.10.2026. Verfasst von S. Pinjala und 6 weiteren Autor:innen.
Abstract (Originalsprache)
Introduction/Purpose: Large Vessel Occlusions (LVOs) typically refer to a blockage in the internal carotid artery, M1/M2 segments of the middle cerebral artery, basilar artery, or the vertebral artery, which can be fatal or lead to long-term disability. Artificial Intelligence algorithms such as RAPID and AIDOC have recently emerged as tools to facilitate the rapid identification of LVO’s. This study evaluates AIDOC’s detection of LVOs and investigates perfusion characteristics associated with false-negative results. Materials and Methods: A retrospective review of patients was conducted for suspected acute ischemic strokes with CT Angiography. Neuroradiologist interpretations were used to confirm LVOs and then run through AIDOC to determine whether the software correctly identified the occlusion. To further evaluate the accuracy of AIDOC, RAPID-derived perfusion parameters were analyzed to determine whether specific perfusion characteristics were associated with the likelihood of automated LVO detection.
Results
A total of 1,227 charts were reviewed, identifying 97 radiologist-confirmed LVOs. Of these, 75 cases were re-evaluated by AIDOC, with 40 (53.3%) concordant cases in which AIDOC correctly identified the LVO and 35 (46.7%) discordant cases in which AIDOC failed to identify the radiologist-confirmed LVO. Among these 75 cases, 48 had corresponding RAPID perfusion data available for analysis.
Conclusion
AIDOC failed to identify a substantial portion of LVOs. Although no RAPID perfusion parameter was statistically significant, the median hypoperfusion volume and median mismatch volume in concordant cases were higher than in discordant cases. This potentially indicates that LVOs with a greater overall perfusion deficit/tissue at risk were more likely to be identified by AIDOC. Understanding the characteristics of LVOs missed by AI algorithms may help understand the shortcomings of AI-based vascular imaging interpretation algorithms and help clinicians recognize where greater caution with these programs is warranted.
Zitieren
APA
Pinjala, S., Khokhar, W., Gorecki, J., Kumar, S., Mehta, R., Martin, R., & Koenigsberg, R. (2026). Abstract 1191: When AI Misses: Perfusion Characteristics Associated With Large Vessel Occlusion Detection. Stroke: Vascular and Interventional Neurology, 6(Suppl_1). https://doi.org/10.1161/svi270000_1191
Vancouver
Pinjala S, Khokhar W, Gorecki J, Kumar S, Mehta R, Martin R, et al. Abstract 1191: When AI Misses: Perfusion Characteristics Associated With Large Vessel Occlusion Detection. Stroke: Vascular and Interventional Neurology. 2026;6(Suppl_1). doi:10.1161/svi270000_1191
BibTeX
@article{Pinjala2026,
author = {Pinjala, S. and Khokhar, W. and Gorecki, J. and Kumar, S. and Mehta, R. and Martin, R. and Koenigsberg, R.},
title = {Abstract 1191: When AI Misses: Perfusion Characteristics Associated With Large Vessel Occlusion Detection},
journal = {Stroke: Vascular and Interventional Neurology},
year = {2026},
volume = {6},
number = {Suppl_1},
doi = {10.1161/svi270000_1191}
}
EUVIMED