EUVIMEDEUVIMED entdecken
Systematische Übersicht

Abstract 1154: Comparative Safety And Effectiveness Of Rescue Balloon Angioplasty Versus Rescue Stenting After Failed Thrombectomy in ICAS/ICAD: A Systematic Review And Meta- analysis

A. Adatrow, A. Chacon, M. Jatty, D. Hijazi, C. Nickele, L. Elijovich, V. Inoa-Acosta, J. A. Grossberg, A. M. Alawieh, N. Goyal

Stroke: Vascular and Interventional Neurology · 18.10.2026 · 6 (Suppl_1)

DOI: 10.1161/svi270000_1154 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Stroke: Vascular and Interventional Neurology, erschienen am 18.10.2026. Verfasst von A. Adatrow und 9 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Mechanical thrombectomy (MT) is the first-line therapy for large vessel occlusion (LVO) in acute ischemic stroke, yet intracranial atherosclerotic stenosis/disease (ICAS/ICAD) remains a frequent cause of failed recanalization, predisposing to distal embolization and early reocclusion. Rescue balloon angioplasty and rescue stenting are the two principal salvage strategies when MT fails. Stenting provides immediate luminal scaffolding and resists elastic recoil but requires acute dual antiplatelet therapy in recently infarcted tissue, whereas angioplasty avoids this exposure at the expense of a greater risk of recoil and reocclusion; which strategy is preferable remains uncertain. We performed a systematic review and meta-analysis to compare the safety and effectiveness of rescue balloon angioplasty versus rescue stenting.

Methods

A systematic literature search of PubMed, Embase and Scopus through July 2026 identified studies reporting outcomes of rescue balloon angioplasty or rescue stenting after failed or incomplete MT for ICAS/ICAD-related LVO. Both single-arm and comparative studies were included. The primary analysis was restricted to studies reporting both techniques within the same cohort, from which within-study odds ratios (OR) were pooled; pooled event rates were additionally generated for each technique across all included studies. Outcomes were 90-day modified Rankin Scale (mRS) 0-2, successful recanalization (mTICI 2b-3), symptomatic intracranial hemorrhage (sICH) and 90-day mortality. Random-effects models were used to generate pooled estimates, and sensitivity analyses included leave-one-out and influence diagnostics.

Results

A total of 27 studies were included, of which six reported both techniques within the same cohort and formed the primary comparison. sICH was significantly more frequent after stenting (4 studies, 341 vs 289 patients; OR 3.09 [95% CI: 1.43-6.69]; p=0.004; I2=0%), consistent with the pooled single-arm rates (9.9% [95% CI: 7.9%-12.3%] vs 3.7% [95% CI: 2.1%-6.6%]). No difference was observed in functional independence (5 studies, 373 vs 303 patients; OR 0.60 [95% CI: 0.25-1.45]; p=0.26; pooled rates 49.8% vs 47.2%) or in 90-day mortality (5 studies, 494 vs 341 patients; OR 0.98 [95% CI: 0.68-1.41]; p=0.90; pooled rates 19% vs 23 %). Successful recanalization showed a non-significant trend favoring stenting (3 studies, 142 vs 257 patients; OR 2.06 [95% CI: 0.96-4.41]; p=0.06; pooled rates 90.5% vs 81.2%). Heterogeneity across the head-to-head studies was absent for sICH, recanalization and mortality (I2=0%) and moderate for functional independence (I2=70%).

Conclusion

After failed thrombectomy for ICAS/ICAD-related LVO, rescue stenting and balloon angioplasty were associated with comparable functional independence and 90-day mortality, with a nonsignificant trend toward higher successful recanalization with stenting. However, rescue stenting was associated with approximately three-fold higher odds of sICH. Given the observational nature of the available evidence, these findings do not support the routine preferential use of stenting as a first-line rescue strategy and warrant confirmation in prospective comparative studies.

Zitieren

APA

Adatrow, A., Chacon, A., Jatty, M., Hijazi, D., Nickele, C., Elijovich, L., Inoa-Acosta, V., Grossberg, J. A., Alawieh, A. M., & Goyal, N. (2026). Abstract 1154: Comparative Safety And Effectiveness Of Rescue Balloon Angioplasty Versus Rescue Stenting After Failed Thrombectomy in ICAS/ICAD: A Systematic Review And Meta- analysis. Stroke: Vascular and Interventional Neurology, 6(Suppl_1). https://doi.org/10.1161/svi270000_1154

Vancouver

Adatrow A, Chacon A, Jatty M, Hijazi D, Nickele C, Elijovich L, et al. Abstract 1154: Comparative Safety And Effectiveness Of Rescue Balloon Angioplasty Versus Rescue Stenting After Failed Thrombectomy in ICAS/ICAD: A Systematic Review And Meta- analysis. Stroke: Vascular and Interventional Neurology. 2026;6(Suppl_1). doi:10.1161/svi270000_1154

BibTeX
@article{Adatrow2026,
  author = {Adatrow, A. and Chacon, A. and Jatty, M. and Hijazi, D. and Nickele, C. and Elijovich, L. and Inoa-Acosta, V. and Grossberg, J. A. and Alawieh, A. M. and Goyal, N.},
  title = {Abstract 1154: Comparative Safety And Effectiveness Of Rescue Balloon Angioplasty Versus Rescue Stenting After Failed Thrombectomy in ICAS/ICAD: A Systematic Review And Meta- analysis},
  journal = {Stroke: Vascular and Interventional Neurology},
  year = {2026},
  volume = {6},
  number = {Suppl_1},
  doi = {10.1161/svi270000_1154}
}
Kostenlos starten →