EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Ultra-High-Resolution Photon-Counting CT Angiography for Noninvasive Detection of Neurovascular In-Stent Restenosis

Chun-Qiu Su, Chun Zhou iD, Peng-Fei Wu, Qing Li, Tao Zhang, Ji-Liang Chen iD, Xiao-Quan Xu iD, Hai-Bin Shi, Sheng Liu iD, Fei-Yun Wu, Shan-Shan Lu iD

Stroke · 2026-08 · 57 (8) · 2417-2425

DOI: 10.1161/strokeaha.126.055371 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Stroke, 2026-08. Verfasst von Chun-Qiu Su und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology (C.-Q.S., P.-F.W., Q.L., T.Z., X.-Q.X., F.-Y.W., S.-S.L.), The First Affiliated Hospital with Nanjing Medical University, Jia…. Hauptthemen laut MEDLINE: Stents, Computed Tomography Angiography, Graft Occlusion, Vascular. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Noninvasive detection of neurovascular in-stent restenosis (ISR) remains challenging because of blooming artifacts and limited spatial resolution on conventional computed tomography angiography (CTA). Ultra-high-resolution (UHR) photon-counting detector CTA (PCD-CTA) may offer an improved approach for accurate ISR detection, potentially overcoming these challenges. METHODS: In this prospective study, consecutive patients who had undergone neurovascular stent implantation were enrolled at The First Affiliated Hospital of Nanjing Medical University between July and November 2025. All participants underwent UHR PCD-CTA. Simulated energy-integrating detector CTA data sets were reconstructed from the same raw data to approximate conventional CTA for comparison. Two blinded radiologists independently assessed subjective image quality, diagnostic confidence for ISR, and visualization of in-stent intimal hyperplasia and low-attenuation plaque in stents without restenosis. Diagnostic performance for ISR detection was evaluated on a stent-based level, using digital subtraction angiography as the reference standard when available. RESULTS: Forty-three participants (mean age, 63.1 years ± 9.5; 8 women) with 51 stents were included. ISR was present in 14 stents and absent in 37; digital subtraction angiography was available for 26 stents, including all stents with ISR. Compared with simulated energy-integrating detector CTA, UHR PCD-CTA demonstrated significantly higher subjective image quality ( P =0.004) and diagnostic confidence for ISR ( P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

StentsComputed Tomography AngiographyGraft Occlusion, VascularHumansFemaleProspective StudiesMiddle AgedMaleAgedAngiography, Digital SubtractionCerebral Angiography

Stichwörter der Autor:innen

CT angiographyartifactsdigital subtraction angiographystentsvascular patency

Autor:innen und Institutionen

  • Department of Radiology (C.-Q.S., P.-F.W., Q.L., T.Z., X.-Q.X., F.-Y.W., S.-S.L.), The First Affiliated Hospital with Nanjing Medical University, Jiangsu Province, China.
  • Department of Interventional Radiology (C.Z., H.-B.S., S.L.), The First Affiliated Hospital with Nanjing Medical University, Jiangsu Province, China.
  • CT Collaboration, Siemens Healthineers, Shanghai, China (J.-L.C.).

ORCID-Profile: Chun Zhou, Ji-Liang Chen, Xiao-Quan Xu, Sheng Liu, Shan-Shan Lu

Zitieren

APA

Su, C. Q., Zhou, C., Wu, P. F., Li, Q., Zhang, T., Chen, J. L., Xu, X. Q., Shi, H. B., Liu, S., Wu, F. Y., & Lu, S. S. (2026). Ultra-High-Resolution Photon-Counting CT Angiography for Noninvasive Detection of Neurovascular In-Stent Restenosis. Stroke, 57(8), 2417-2425. https://doi.org/10.1161/strokeaha.126.055371

Vancouver

Su CQ, Zhou C, Wu PF, Li Q, Zhang T, Chen JL, et al. Ultra-High-Resolution Photon-Counting CT Angiography for Noninvasive Detection of Neurovascular In-Stent Restenosis. Stroke. 2026;57(8):2417-2425. doi:10.1161/strokeaha.126.055371

BibTeX
@article{Su2026,
  author = {Su, Chun-Qiu and Zhou, Chun and Wu, Peng-Fei and Li, Qing and Zhang, Tao and Chen, Ji-Liang and Xu, Xiao-Quan and Shi, Hai-Bin and Liu, Sheng and Wu, Fei-Yun and Lu, Shan-Shan},
  title = {Ultra-High-Resolution Photon-Counting CT Angiography for Noninvasive Detection of Neurovascular In-Stent Restenosis},
  journal = {Stroke},
  year = {2026},
  volume = {57},
  number = {8},
  pages = {2417--2425},
  doi = {10.1161/strokeaha.126.055371}
}
Kostenlos starten →