EUVIMEDEUVIMED entdecken
Systematische ÜbersichtMetaanalyseOpen Access

Stroke Risk After Bioprosthetic Aortic Valve Replacement in Aortic Stenosis: Systematic Review and Meta-Analysis

Tarek Bou Dargham iD, Sara Hassani iD, Brian Mac Grory iD, Melissa A Daubert iD, Dylan Ryan iD, Tracy Truong iD, Mohamad B Moumneh, Samantha J Kaplan iD, Wuwei Feng iD, Nada El Husseini iD

Stroke · 2026-06 · 57 (6) · 1643-1657

DOI: 10.1161/strokeaha.125.053422 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Stroke, 2026-06. Verfasst von Tarek Bou Dargham und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neurosurgery (T.B.D.), Duke University School of Medicine, Durham, NC. Hauptthemen laut MEDLINE: Aortic Valve, Aortic Valve Stenosis, Bioprosthesis, Heart Valve Prosthesis. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 89 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS, NINDS NIH HHS, NCATS NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Stroke is a possible complication after bioprosthetic aortic valve replacement (AVR) for severe aortic stenosis (AS), impacting morbidity and mortality. Accurate estimates of the proportion of individuals who experience stroke within and beyond the periprocedural period after transcatheter AVR (TAVR), surgical AVR, and valve-in-valve (ViV) replacement are essential for management and prognostication. The objective was to determine the proportion of adults aged >18 who experienced an ischemic stroke after bioprosthetic AVR for AS. METHODS: A systematic search of MEDLINE, Embase, and Web of Science was conducted from database inception through March 2024. Studies reporting on stroke rates at least 90 days after bioprosthetic AVR for severe AS, including ViV procedures, and meeting predefined eligibility criteria were included. The pooled proportion of individuals experiencing a stroke was estimated for TAVR and ViV procedures, whereas comparative analyses between TAVR and surgical AVR were performed using mixed-effects models in studies directly comparing both procedures. RESULTS: Twenty-seven studies were included in the native AS treatment cohort, and 5 in the ViV subanalysis. In native AS, the pooled 30-day proportion of individuals who had a stroke after TAVR was 3.0% (95% CI, 2.5–3.9), with different studies reporting major and minor stroke proportions of 1.7% each. At 1 year, all stroke proportion was 5.0% (95% CI, 4.0–6.0), major stroke was 3.0%, and minor stroke was 2.0%. Comparative analysis demonstrated that TAVR was associated with significantly lower odds of all stroke at 30 days compared with surgical AVR (odds ratio, 0.73 [95% CI, 0.57–0.93]). No significant difference in the proportions of individuals who had a stroke was observed in TAVR versus surgical AVR at 1, 2, or 5 years. In the ViV cohort, the pooled 30-day and 1-year all stroke proportion after ViV was 2.0% (95% CI, 1.0–3.0) and 3.0% (95% CI, 2.0–6.0), respectively. CONCLUSIONS: This meta-analysis provides updated estimates of stroke after bioprosthetic AVR for AS, capturing risk beyond the early periprocedural period. Future studies should investigate the causes of long-term stroke post-AVR, the effects of different antithrombotic therapies on the risk of stroke, as well as the potential impact of these procedures on short and long-term cognitive function.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic ValveAortic Valve StenosisBioprosthesisHeart Valve ProsthesisHeart Valve Prosthesis ImplantationPostoperative ComplicationsStrokeHumansRisk FactorsTranscatheter Aortic Valve Replacement

Stichwörter der Autor:innen

aortic valve stenosisheart valvesriskstroketranscatheter aortic valve replacement

Autor:innen und Institutionen

  • Department of Neurosurgery (T.B.D.), Duke University School of Medicine, Durham, NC.
  • Department of Neurology, Feinberg School of Medicine Northwestern University, Chicago IL (S.H.).
  • Department of Neurology (B.M.G., D.R., W.F., N.E.H.), Duke University School of Medicine, Durham, NC.
  • Division of Cardiology, Department of Medicine (M.A.D.), Duke University School of Medicine, Durham, NC.
  • Department of Biostatistics & Bioinformatics (T.T.), Duke University School of Medicine, Durham, NC.
  • Inova Center of Outcomes Research, Inova Heart and Vascular, Fairfax, VA (M.B.M.).

ORCID-Profile: Tarek Bou Dargham, Sara Hassani, Brian Mac Grory, Melissa A Daubert, Dylan Ryan, Tracy Truong, Samantha J Kaplan, Wuwei Feng, Nada El Husseini

Förderung

  • NHLBI NIH HHS
  • NINDS NIH HHS
  • NCATS NIH HHS

Zitieren

APA

Bou Dargham, T., Hassani, S., Mac Grory, B., Daubert, M. A., Ryan, D., Truong, T., Moumneh, M. B., Kaplan, S. J., Feng, W., & El Husseini, N. (2026). Stroke Risk After Bioprosthetic Aortic Valve Replacement in Aortic Stenosis: Systematic Review and Meta-Analysis. Stroke, 57(6), 1643-1657. https://doi.org/10.1161/strokeaha.125.053422

Vancouver

Bou Dargham T, Hassani S, Mac Grory B, Daubert MA, Ryan D, Truong T, et al. Stroke Risk After Bioprosthetic Aortic Valve Replacement in Aortic Stenosis: Systematic Review and Meta-Analysis. Stroke. 2026;57(6):1643-1657. doi:10.1161/strokeaha.125.053422

BibTeX
@article{BouDargham2026,
  author = {Bou Dargham, Tarek and Hassani, Sara and Mac Grory, Brian and Daubert, Melissa A and Ryan, Dylan and Truong, Tracy and Moumneh, Mohamad B and Kaplan, Samantha J and Feng, Wuwei and El Husseini, Nada},
  title = {Stroke Risk After Bioprosthetic Aortic Valve Replacement in Aortic Stenosis: Systematic Review and Meta-Analysis},
  journal = {Stroke},
  year = {2026},
  volume = {57},
  number = {6},
  pages = {1643--1657},
  doi = {10.1161/strokeaha.125.053422}
}
Kostenlos starten →