EUVIMEDEUVIMED entdecken
Crossref

Abstract WP93: Providing Stroke Reports to Emergency Medical Services (EMS) Agencies Improves Data Quality in Michigan's Statewide EMS Data Repository

Justin Allen, Adrienne Nickles, Ghada Ibrahim, Beth Anderson, Krystal Quartermus, John A Oostema

Stroke · 2024-02 · 55 (Suppl_1)

DOI: 10.1161/str.55.suppl_1.wp93 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Stroke, 2024-02. Verfasst von Justin Allen und 5 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Intro: The Michigan Stroke Program (MiSP) monitors statewide EMS stroke care performance and data quality. Starting in 2018, quarterly performance and outcome benchmark data were shared with EMS agency partners to support prehospital quality improvement (QI) for stroke patients.

Objective

To improve EMS data quality and prehospital stroke care performance.

Methods

This is a retrospective before and after study of the impact of tailored QI interventions to improve EMS compliance with three prehospital stroke quality metrics selected by MiSP EMS partners: (prehospital stroke scale documentation, last known well documentation, and prehospital notification). Five MiSP EMS partners participated in the intervention which consisted of provision of quarterly performance reports generated from linked data from Michigan’s EMS Information System and the Michigan Stroke Registry. The MiSP team reviewed agency performance with EMS leadership to select the target measures for intervention and then assisted in development of a QI plan to improve agency performance. Measure compliance was compared from three months prior to and six months after data quality solutions were implemented.

Results

Through data sharing and communication with EMS agencies and EMS software data vendors, common themes were identified related to poor data quality beginning in January 2020. A sample of agencies and resolutions to address these issues are displayed in the Table. Compliance with the targeted metric improved significantly at each agency at three and six months following intervention.

Conclusions

Analysis of EMS data and sharing performance data directly with EMS agency partners identified correctable data quality issues negatively impacting EMS quality measures. Correcting these issues led to dramatic and sustained improvement in EMS quality metric compliance. This approach may serve as a model for improving the accuracy of EMS performance data in state-level EMS registries.

Zitieren

APA

Allen, J., Nickles, A., Ibrahim, G., Anderson, B., Quartermus, K., & Oostema, J. A. (2024). Abstract WP93: Providing Stroke Reports to Emergency Medical Services (EMS) Agencies Improves Data Quality in Michigan's Statewide EMS Data Repository. Stroke, 55(Suppl_1). https://doi.org/10.1161/str.55.suppl_1.wp93

Vancouver

Allen J, Nickles A, Ibrahim G, Anderson B, Quartermus K, Oostema JA. Abstract WP93: Providing Stroke Reports to Emergency Medical Services (EMS) Agencies Improves Data Quality in Michigan's Statewide EMS Data Repository. Stroke. 2024;55(Suppl_1). doi:10.1161/str.55.suppl_1.wp93

BibTeX
@article{Allen2024,
  author = {Allen, Justin and Nickles, Adrienne and Ibrahim, Ghada and Anderson, Beth and Quartermus, Krystal and Oostema, John A},
  title = {Abstract WP93: Providing Stroke Reports to Emergency Medical Services (EMS) Agencies Improves Data Quality in Michigan's Statewide EMS Data Repository},
  journal = {Stroke},
  year = {2024},
  volume = {55},
  number = {Suppl_1},
  doi = {10.1161/str.55.suppl_1.wp93}
}
Kostenlos starten →