Variable Interferences Dictate Different Cutoffs for Aldosterone Measured by Liaison and iSYS Chemiluminescence Immunoassays for the Seated Saline Suppression Test
Journal of the American Heart Association · 18.11.2026
DOI: 10.1161/jaha.126.051573 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of the American Heart Association, online erschienen am 18.11.2026. Verfasst von Graeme Eisenhofer und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine III University Hospital Carl Gustav Carus, Technische Universität Dresden Dresden Germany. Die Arbeit nennt 36 Literaturangaben.
Abstract (Originalsprache)
Background
Variable macromolecular‐related interferences with different chemiluminescence immunoassays (CLIA) of plasma aldosterone, particularly at low concentrations during confirmatory tests, are a previously unrecognized problem. We therefore hypothesized that cutoffs for measurements of aldosterone for the seated saline suppression test require tailoring according to the particular immunoassay.
Methods
Multicenter study involving 609 patients with suspected primary aldosteronism who underwent seated saline suppression tests with aldosterone measured by liquid chromatography–mass spectrometry (LC–MS/MS) compared with iSYS or Liaison CLIAs in 285 and 286 respective patients and a different LC–MS/MS method in 38 others. Cutoffs for plasma aldosterone were derived from receiver operating characteristic curves after classification of patients with (n=181) and without primary aldosteronism (n=336) by methods independent of confirmatory tests. For 92 patients classifications were not achieved.
Results
Youden's‐index derived cutoffs for postsaline infusion plasma aldosterone were 300 and 272 pmol/L for measurements by respective Liaison and iSYS CLIAs compared with 169 pmol/L by LC–MS/MS. At those cutoffs, respective diagnostic sensitivities for Liaison and iSYS immunoassays and LC–MS/MS were 90% (CI, 84–97), 91% (CI, 86–97), and 98% (CI, 96–100) with specificities of 86% (CI, 80–91), 94% (CI, 80–91), and 90% (CI, 86–93). Improved disease confirmation according to specificities of 95% for measurements by Liaison and iSYS CLIAs and LC–MS/MS were provided by respective cutoffs of 436, 297, and 243 pmol/L but with reduced sensitivities of 64% (CI, 53–75), 85% (CI, 78–92), and 78% (CI, 72–84).
Conclusions
Cutoffs for CLIA‐based measurements of aldosterone during the seated saline suppression test are higher than those for LC–MS/MS and vary according to the specific immunoassay. Gray areas around cutoffs, particularly extensive for the Liaison CLIA, must also be considered. Registration https://drks.de/search/en/trial/DRKS00017084 .
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medicine III University Hospital Carl Gustav Carus, Technische Universität Dresden Dresden Germany.
- New South Wales Health Pathology, Department of Chemical Pathology Prince of Wales Hospital and School Public Health, University of Sydney Sydney NSW Australia.
- Centre for Endocrinology and Reproductive Health, Hudson Institute of Medical Research, and Department of Medicine Monash University Clayton VIC Australia.
- Division of Endocrinology and Diabetes University Hospital, University of Würzburg Würzburg Germany.
- Department of Medicine IV University Hospital, Ludwig Maximilian University Munich Munich Germany.
- Department of Endocrinology, Diabetology and Clinical Nutrition University Hospital Zurich, University of Zurich and the LOOP-Zurich Medical Research Center Zurich Switzerland.
ORCID-Profile: Graeme Eisenhofer, Andrea R Horvath, Jun Yang, Hanna Remde, Martin Reincke, Tracy Ann Williams, Felix Beuschlein, Jacques W M Lenders, Christina Pamporaki
Zitieren
APA
Eisenhofer, G., Horvath, A. R., Yang, J., Fuss, C. T., Remde, H., Reincke, M., Williams, T. A., Beuschlein, F., Lenders, J. W. M., & Pamporaki, C. (2026). Variable Interferences Dictate Different Cutoffs for Aldosterone Measured by Liaison and iSYS Chemiluminescence Immunoassays for the Seated Saline Suppression Test. Journal of the American Heart Association. https://doi.org/10.1161/jaha.126.051573
Vancouver
Eisenhofer G, Horvath AR, Yang J, Fuss CT, Remde H, Reincke M, et al. Variable Interferences Dictate Different Cutoffs for Aldosterone Measured by Liaison and iSYS Chemiluminescence Immunoassays for the Seated Saline Suppression Test. Journal of the American Heart Association. 2026. doi:10.1161/jaha.126.051573
BibTeX
@article{Eisenhofer2026,
author = {Eisenhofer, Graeme and Horvath, Andrea R and Yang, Jun and Fuss, Carmina T and Remde, Hanna and Reincke, Martin and Williams, Tracy Ann and Beuschlein, Felix and Lenders, Jacques W M and Pamporaki, Christina},
title = {Variable Interferences Dictate Different Cutoffs for Aldosterone Measured by Liaison and iSYS Chemiluminescence Immunoassays for the Seated Saline Suppression Test},
journal = {Journal of the American Heart Association},
year = {2026},
doi = {10.1161/jaha.126.051573}
}
EUVIMED