Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of the American Heart Association, erschienen am 20.10.2026. Verfasst von Raviteja R Guddeti und 14 weiteren Autor:innen. Beteiligte Einrichtung: The Carl and Edyth Lindner Center for Research and Education at The Christ Hospital Cincinnati OH USA. Hauptthemen laut MEDLINE: Radiation Protection, Cardiac Catheterization, Occupational Exposure, Radiation Exposure. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Enhanced radiation protection devices (ERPDs) have the potential to reduce occupational risks in the cardiac catheterization laboratory. We aimed to investigate scatter radiation exposure to various cardiac catheterization laboratory members using 2 ERPDs.

Methods

We prospectively allocated cases to 3 different shielding conditions: standard shielding (group 1), EggNest Protect ERPD (group 2), and EggNest Complete ERPD (group 3). Real‐time dosimetry was used to measure radiation exposure at 3 positions: primary operator (position 1), assistant (position 2), and circulating nurse (position 3). Effective dose equivalent was estimated (annualized to 300 cases/y).

Results

A total of 135 patients were included in the study (mean age, 68±11 years; 73% men). For position 1, annualized effective dose equivalent ‐1 doses were 51.4 (19.1–101.3), 7.0 (2.3–21.5), and 2.4 (0.9–6.2) mRem for groups 1, 2, and 3, respectively ( P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiation ProtectionCardiac CatheterizationOccupational ExposureRadiation ExposureRadiation InjuriesRadiography, InterventionalHumansProspective StudiesRadiation DosageFemaleMaleAgedEquipment Design

Stichwörter der Autor:innen

cardiac catheterization laboratorycoronaryradiation protection

Autor:innen und Institutionen

  • The Carl and Edyth Lindner Center for Research and Education at The Christ Hospital Cincinnati OH USA.
  • Overlake Medical Center Bellevue WA USA.
  • Icahn School of Medicine at Mount Sinai New York NY USA.

ORCID-Profile: Raviteja R Guddeti, Robert F Riley, Jacob Kamen, Sitaramesh Emani, John D Corl, Puvi Seshiah, Timothy D Henry, Dean J Kereiakes, Santiago Garcia

Zitieren

APA

Guddeti, R. R., Schmidt, C. W., Riley, R. F., Kamen, J., Frizzell, J., Haddox, K., Kong, J., Rudick, S., Emani, S., Corl, J. D., Seshiah, P., Henry, T. D., Kereiakes, D. J., Tribble, S., & Garcia, S. (2026). Evaluating Standard Shielding Versus Novel Enhanced Radiation Protection Devices in the Cardiac Catheterization Laboratory. Journal of the American Heart Association, 15(20). https://doi.org/10.1161/jaha.126.050577

Vancouver

Guddeti RR, Schmidt CW, Riley RF, Kamen J, Frizzell J, Haddox K, et al. Evaluating Standard Shielding Versus Novel Enhanced Radiation Protection Devices in the Cardiac Catheterization Laboratory. Journal of the American Heart Association. 2026;15(20). doi:10.1161/jaha.126.050577

BibTeX
@article{Guddeti2026,
  author = {Guddeti, Raviteja R and Schmidt, Christian W and Riley, Robert F and Kamen, Jacob and Frizzell, Jarrod and Haddox, Korey and Kong, James and Rudick, Steven and Emani, Sitaramesh and Corl, John D and Seshiah, Puvi and Henry, Timothy D and Kereiakes, Dean J and Tribble, Samantha and Garcia, Santiago},
  title = {Evaluating Standard Shielding Versus Novel Enhanced Radiation Protection Devices in the Cardiac Catheterization Laboratory},
  journal = {Journal of the American Heart Association},
  year = {2026},
  volume = {15},
  number = {20},
  doi = {10.1161/jaha.126.050577}
}
Kostenlos starten →