Comparative Accuracy of the European Society of Cardiology Rapid Rule‐Out and Rule‐In Protocols for Diagnosing Non−ST‐Segment−Elevation Myocardial Infarction: A Network Meta‐Analysis
Journal of the American Heart Association · 18.11.2026
DOI: 10.1161/jaha.125.047758 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of the American Heart Association, online erschienen am 18.11.2026. Verfasst von Hirotaka Ohtake und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Emergency Medicine and General Internal Medicine Fujita Health University School of Medicine Toyoake Japan. Die Arbeit nennt 291 Literaturangaben.
Abstract (Originalsprache)
Background
The European Society of Cardiology rapid rule‐out and rule‐in protocols using hs‐cTns (high‐sensitivity cardiac troponins) with blood collection at 0 and 1 hour (0/1 hour), 0 and 2 hours (0/2 hours), and 0 and 3 hours (0/3 hours) are accurate and widely used for evaluating non–ST‐segment–elevation myocardial infarction. This network meta‐analysis aimed to identify the best performing hs‐cTn assay.
Methods
We conducted database searches up to January 15, 2026, a dual screening and eligibility assessment, independent data extraction and risk of bias assessment, a network meta‐analysis of diagnostic accuracy, and assessment of the certainty of evidence. Only full‐paired diagnostic accuracy studies conducted in the emergency department were included.
Results
Ten prospective studies (15 publications) comparing 10 assays using the 0‐/1‐hour algorithm (n=8769), 0‐/2‐hour algorithm (n=1881), and 0‐/3‐hour algorithm (n=1236) were included. Comparisons between newer and conventional assays largely stemmed from a single‐source study. Across all assays, the European Society of Cardiology 0‐/1‐hour algorithm demonstrated high sensitivity (summary point estimate range: 97.8%–99.8%). Furthermore, it maintained high specificity (89.8%–98.1%), with no assay showing clear superiority. The summary sensitivity and specificity did not show significant differences across assays after adjusting for biases because of imperfect reference standards. Comparative data in the European Society of Cardiology 0‐/2‐hour and 0‐/3‐hour algorithms were limited.
Conclusions
Evidence remains insufficient to establish the superiority of any specific hs‐cTn assay within the European Society of Cardiology 0‐/1‐hour algorithm. Although practical considerations may currently guide selection, continued validation of newer assays remains necessary.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Emergency Medicine and General Internal Medicine Fujita Health University School of Medicine Toyoake Japan.
- Exeter Test Group, University of Exeter Medical School University of Exeter Exeter, Devon UK.
- NIHR ARC South West Peninsula University of Exeter Medical School Exeter UK.
- Department of Cardiology Stavanger University Hospital Stavanger Norway.
- Emergency Care Clinic Haukeland University Hospital Bergen Norway.
- Department of Clinical Medicine University of Bergen Norway.
ORCID-Profile: Hirotaka Ohtake, Teruhiko Terasawa, Zhivko Zhelev, Morwenna Rogers, Ingar Z Restan, Viola I L Thulin, Kristin M Aakre, Luca Koechlin, Jasper Boeddinghaus, Pedro Lopez-Ayala, Christian Mueller, Chris Hyde
Zitieren
APA
Ohtake, H., Terasawa, T., Zhelev, Z., Rogers, M., Peters, J. L., Restan, I. Z., Thulin, V. I. L., Aakre, K. M., Koechlin, L., Boeddinghaus, J., Lopez-Ayala, P., Mueller, C., Iwata, M., & Hyde, C. (2026). Comparative Accuracy of the European Society of Cardiology Rapid Rule‐Out and Rule‐In Protocols for Diagnosing Non−ST‐Segment−Elevation Myocardial Infarction: A Network Meta‐Analysis. Journal of the American Heart Association. https://doi.org/10.1161/jaha.125.047758
Vancouver
Ohtake H, Terasawa T, Zhelev Z, Rogers M, Peters JL, Restan IZ, et al. Comparative Accuracy of the European Society of Cardiology Rapid Rule‐Out and Rule‐In Protocols for Diagnosing Non−ST‐Segment−Elevation Myocardial Infarction: A Network Meta‐Analysis. Journal of the American Heart Association. 2026. doi:10.1161/jaha.125.047758
BibTeX
@article{Ohtake2026,
author = {Ohtake, Hirotaka and Terasawa, Teruhiko and Zhelev, Zhivko and Rogers, Morwenna and Peters, Jaime L and Restan, Ingar Z and Thulin, Viola I L and Aakre, Kristin M and Koechlin, Luca and Boeddinghaus, Jasper and Lopez-Ayala, Pedro and Mueller, Christian and Iwata, Mitsunaga and Hyde, Chris},
title = {Comparative Accuracy of the European Society of Cardiology Rapid Rule‐Out and Rule‐In Protocols for Diagnosing Non−ST‐Segment−Elevation Myocardial Infarction: A Network Meta‐Analysis},
journal = {Journal of the American Heart Association},
year = {2026},
doi = {10.1161/jaha.125.047758}
}
EUVIMED